EPR PVC Copper Tape Shield 15kV

EPR PVC Copper Tape Shield 15kV

Power Cable EPR PVC Copper Tape Shield 15kV

EPR PVC Copper Tape Shield 15kV

3FE-0201, 3FE-0101, 3FE-1011, 3FE-2021, 3FE-3031, 3FE-4041, 3FE-2501, 3FE-3501, 3FE-5001, 3FE-7501, 3FE-10001

Somos Especialistas en Cables. Distribuimos en toda la Republica Mexicana: Innovative Trade Center, Tel: (664) 621 33 36 / 621 30 09 ventas@innovative.com.mx, soporte@innovative.com.mx, Tijuana, B. C. www.innovative.com.mx

Power Cable EPR PVC Copper Tape Shield 15kV

aislamiento de EPR
El forro de PVC
blindado
nivel de aislamiento 133%
ESPECIFICACIONES DE
1. CONDUCTOR: Clase B Trenzado, recocido, cobre desnudo según la norma ASTM B-3, (trenzado compacto según la norma ASTM B-496 está disponible). escudo Strand es un semiconductor extruido,
compuesto termoestable
2. AISLAMIENTO: Caucho de etileno propileno (EPR), propiedades físicas y eléctricas están en conformidad con ICEA S-93-639 (NEMA WC74)
3. AISLAMIENTO SHIELD: blindaje de aislamiento extruido termoestable semiconductor. Escudo metálico es una cinta de cobre sin recubrimiento 5 mil aplicada helicoidalmente
4. CHAQUETA EN GENERAL: La luz solar resistente de vinilo negro de vinilo (PVC)
5. NORMAS: Listado Tipo MV-105 por UL 1072 y cumple con los requisitos de ICEA S-93-639. Tamaños 1/0 y mayor indicación «para uso de la TC» y pasar UL 1685 70.000 Btu / hr
prueba de la llama
6. AMPACIDAD: Sobre la base de tres cables conductores individuales aislados en el conducto de aire por 2008 Cuadro NEC 310.73 con una temperatura del conductor de 90 ° C y una temperatura ambiente
de 40 ° C
7. Temperatura: 105 ° C
8. Voltaje: 15 kV
APLICACIONES
Para su uso en circuitos de potencia de hasta 15 kV cuando se instala en el aire abierto, conducto, el conducto, o directamente enterrados, para lugares húmedos y secos. Se utiliza para aplicaciones de potencia en plantas químicas,
refinerías, fábricas de acero, plantas industriales, subestaciones y centrales eléctricas.

Los cables con trenzado compacto tienen diámetros totales ligeramente más pequeñas. Diámetros y pesos pueden variar entre los fabricantes

Power Cable EPR PVC Copper Tape Shield 15kV

EPR insulation
PVC jacket
Shielded
133% insulation level
SPECIFICATIONS OF
1. CONDUCTOR: Class B stranded, annealed, bare copper per ASTM B-3, (compact stranding per ASTM B-496 is available). Strand shield is an extruded semiconducting,
thermosetting compound
2. INSULATION: Ethylene Propylene Rubber (EPR), physical and electrical properties are in accordance with ICEA S-93-639 (NEMA WC74)
3. INSULATION SHIELD: Extruded semiconducting thermoset insulation shield. Metallic shield is a helically applied 5 mil uncoated copper tape
4. OVERALL JACKET: Sunlight-resistant black Polyvinyl Chloride (PVC)
5. STANDARDS: Listed Type MV-105 per UL 1072 and meets the requirements of ICEA S-93-639. Sizes 1/0 and larger marked «for CT use» and pass UL 1685 70,000 Btu/hr
flame test
6. AMPACITY: Based on three single conductor cables in isolated conduit in air per 2008 NEC Table 310.73 with a conductor temperature of 90°C and an ambient temperature
of 40°C
7. TEMPERATURE: 105°C
8. VOLTAGE: 15 kV
APPLICATIONS
For use in power circuits up to 15 kV when installed in open air, conduit, duct, or direct buried, for wet and dry locations. Used for power applications in chemical plants,
refineries, steel mills, industrial plants, utility substations and generating stations.

Cables with compact stranding have slightly smaller overall diameters. Diameters and weights may vary among manufacturers

3FE-0201, 3FE-0101, 3FE-1011, 3FE-2021, 3FE-3031, 3FE-4041, 3FE-2501, 3FE-3501, 3FE-5001, 3FE-7501, 3FE-10001

Power Cable EPR PVC Copper Tape Shield 15kV en: Tijuana, Rosarito, Mexicali, Ensenada, Tecate, San Luis Rio Colorado, Son, La Paz, BCS, Los Cabos BCS, Mexico

Etiquetado con: , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,
Publicado en: Cable y Alambre, Wire and Cable

EPR CPE Unishield 15kV

EPR CPE Unishield 15kV

Power Cable EPR CPE Unishield 15kV

EPR CPE Unishield 15kV

3USC-0201, 3USC-1011, 3USC-2021, 3USC-4041, 3USC-2501, 3USC-3501, 3USC-5001, 3USC-7501, 3USC-10001

Somos Especialistas en Cables. Distribuimos en toda la Republica Mexicana: Innovative Trade Center, Tel: (664) 621 33 36 / 621 30 09 ventas@innovative.com.mx, soporte@innovative.com.mx, Tijuana, B. C. www.innovative.com.mx

Power Cable EPR CPE Unishield 15kV

aislamiento de EPR
chaqueta de CPE
Blindado (UniShield)
nivel de aislamiento 133%
PRESUPUESTO
1. CONDUCTOR: Clase B, de trenzado compacto, de cobre desnudo recocido según la norma ASTM B-3 y B-496, escudo cadena es un compuesto semiconductor extruido
2. AISLAMIENTO: Caucho de etileno propileno (EPR) por ICEA S-93-639 (NEMA WC74)
3. SISTEMA DE SHIELD: Combinación de seis hilos de drenaje de cobre y polietileno clorado semiconductora extruida (CPE)
4. NORMAS: Listado por UL Tipo MV-105 por UL 1072. También se reúne ICEA S-93-639 / NEMA WC74 y ICEA S-97-682. IEEE 1202 pasa prueba de la llama / hr 70.000 BTU. Los tamaños 1/0 y más grande
marcada «La luz del sol-resistente para el uso de CT» y pasar UL 1685 de 70.000 Btu / hr prueba de llama
5. AMPACIDAD: Sobre la base de tres cables conductores individuales aislados en el conducto de aire de acuerdo con la Tabla NEC 310.73 con una temperatura del conductor de 90 ° C y una temperatura ambiente de 40 ° C
6. Temperatura: 105 ° C
7. Voltaje: 15 kV
APLICACIONES
Para su uso en circuitos de potencia de hasta 15 kV cuando se instala en el aire abierto, conducto, conductos, o enterrado directamente en la tierra, para lugares húmedos y secos. Se utiliza para aplicaciones de potencia en química
plantas, refinerías, fábricas de acero, plantas industriales, subestaciones y centrales eléctricas.

Power Cable EPR CPE Unishield 15kV

EPR insulation
CPE jacket
Shielded (Unishield)
133% insulation level
SPECIFICATIONS
1. CONDUCTOR: Class B, compact stranded, annealed bare copper per ASTM B-3 and B-496, strand shield is an extruded semiconducting compound
2. INSULATION: Ethylene Propylene Rubber (EPR) per ICEA S-93-639 (NEMA WC74)
3. SHIELD SYSTEM: Combination of six copper drain wires and extruded semiconducting Chlorinated Polyethylene (CPE) jacket
4. STANDARDS: UL Listed Type MV-105 per UL 1072. Also meets ICEA S-93-639/NEMA WC74 and ICEA S-97-682. Passes IEEE 1202 70,000 Btu/hr flame test. Sizes 1/0 and larger
marked «Sunlight-Resistant for CT use» and pass UL 1685 70,000 Btu/hr flame test
5. AMPACITY: Based on three single conductor cables in isolated conduit in air per NEC Table 310.73 with a conductor temperature of 90°C and an ambient temperature of 40°C
6. TEMPERATURE: 105°C
7. VOLTAGE: 15 kV
APPLICATIONS
For use in power circuits up to 15 kV when installed in open air, conduit, duct, or buried direct in earth, for wet and dry locations. Used for power applications in chemical
plants, refineries, steel mills, industrial plants, utility substations and generating stations.

3USC-0201, 3USC-1011, 3USC-2021, 3USC-4041, 3USC-2501, 3USC-3501, 3USC-5001, 3USC-7501, 3USC-10001

Power Cable EPR CPE Unishield 15kV en: Tijuana, Rosarito, Mexicali, Ensenada, Tecate, San Luis Rio Colorado, Son, La Paz, BCS, Los Cabos BCS, Mexico

Etiquetado con: , , , , , , , , , , , , , , , , , , , , , ,
Publicado en: Cable y Alambre, Wire and Cable

Three Conductor EPR PVC Shielded

Three Conductor EPR PVC Shielded

Power Cable Three Conductor EPR PVC Shielded

Three Conductor EPR PVC Shielded

3JS-0603, 3JS-0403, 3JS-0203, 3JS-1013, 3JS-2023, 3JS-4043, 3JS-3503, 3JS-5003, 3JS-7503

Somos Especialistas en Cables. Distribuimos en toda la Republica Mexicana: Innovative Trade Center, Tel: (664) 621 33 36 / 621 30 09 ventas@innovative.com.mx, soporte@innovative.com.mx, Tijuana, B. C. www.innovative.com.mx

Power Cable Three Conductor EPR PVC Shielded

aislamiento de EPR
El forro de PVC
blindado
Lista UL Tipo MV-105
ESPECIFICACIONES DE
1. CONDUCTOR: Clase B trenzado, de cobre desnudo recocido
2. blindaje del conductor: Conductor se cubre con un compuesto termoestable semiconductor extruido unido al aislamiento
3. AISLAMIENTO: Caucho de etileno propileno (EPR) con la capa semiconductora termoestable y 5 mil escudo cinta de cobre
4. MONTAJE: Los tres conductores están cableados con una hebra de Clase B, conductor de puesta a tierra sin recubrimiento de cobre y cargas adecuadas de conformidad con la norma UL 1072. Una cinta aglutinante es
aplicado en general
5. CHAQUETA general: requisitos de ICEA y UL reunión Sunlight resistente negro cloruro de polivinilo (PVC)
6. NORMAS: Listado Tipo MV-105 por UL 1072 y cumple con los requisitos de ICEA S-93-639 y AEIC CS8. UL 1685 pasa prueba de la llama / hr 70.000 BTU. Los tamaños 1/0 y más grande
la indicación «para uso de la TC»
7. AMPACIDAD: Sobre la base de tres cables conductores individuales aislados en el conducto de aire de acuerdo con la Tabla NEC 310,75 con una temperatura del conductor de 90 ° C y una temperatura ambiente de 40 ° C
8. Temperatura: 105 ° C
9. VOLTAJE: 5 kV 133% y 8 kV 100%
APLICACIONES
Para su uso en circuitos de potencia de hasta 8 kV cuando se instala en el aire abierto, conducto, conducto o enterrado directamente en la tierra, para lugares húmedos y secos. Se utiliza para aplicaciones de potencia en química
plantas, refinerías, fábricas de acero, plantas industriales, subestaciones y centrales eléctricas.

Diámetros y pesos pueden variar entre los fabricantes.

Power Cable Three Conductor EPR PVC Shielded

EPR insulation
PVC jacket
Shielded
UL Listed Type MV-105
SPECIFICATIONS OF
1. CONDUCTOR: Class B stranded, annealed bare copper
2. CONDUCTOR SHIELD: Conductor is covered with an extruded semiconducting thermoset compound bonded to the insulation
3. INSULATION: Ethylene Propylene Rubber (EPR) with thermoset semiconducting layer and 5 mil copper tape shield
4. ASSEMBLY: The three conductors are cabled with a Class B stranded, uncoated copper grounding conductor and suitable fillers in compliance with UL 1072. A binder tape is
applied overall
5. OVERALL JACKET: Sunlight-resistant black Polyvinyl Chloride (PVC) meeting ICEA and UL requirements
6. STANDARDS: Listed Type MV-105 per UL 1072 and meets the requirements of ICEA S-93-639 and AEIC CS8. Passes UL 1685 70,000 Btu/hr flame test. Sizes 1/0 and larger
marked «for CT use»
7. AMPACITY: Based on three single conductor cables in isolated conduit in air per NEC Table 310.75 with a conductor temperature of 90°C and an ambient temperature of 40°C
8. TEMPERATURE: 105°C
9. VOLTAGE: 5 kV 133% and 8 kV 100%
APPLICATIONS
For use in power circuits up to 8 kV when installed in open air, conduit, duct or buried directly in the earth, for wet and dry locations. Used for power applications in chemical
plants, refineries, steel mills, industrial plants, utility substations and generating stations.

Diameters and weights may vary among manufacturers.

3JS-0603, 3JS-0403, 3JS-0203, 3JS-1013, 3JS-2023, 3JS-4043, 3JS-3503, 3JS-5003, 3JS-7503

Power Cable Three Conductor EPR PVC Shielded en: Tijuana, Rosarito, Mexicali, Ensenada, Tecate, San Luis Rio Colorado, Son, La Paz, BCS, Los Cabos BCS, Mexico

Etiquetado con: , , , , , , , , , , , , , , , , , , , , , , , , , , , ,
Publicado en: Cable y Alambre, Wire and Cable

EPR PVC Copper Tape Shield 5kV

EPR PVC Copper Tape Shield 5kV

Power Cable EPR PVC Copper Tape Shield 5kV

EPR PVC Copper Tape Shield 5kV

3DA-0201, 3DA-1011, 3DA-2021, 3DA-4041, 3DA-2501, 3DA-3501, 3DA-5001, 3DA-7501, 3DA-10001

Somos Especialistas en Cables. Distribuimos en toda la Republica Mexicana: Innovative Trade Center, Tel: (664) 621 33 36 / 621 30 09 ventas@innovative.com.mx, soporte@innovative.com.mx, Tijuana, B. C. www.innovative.com.mx

Power Cable EPR PVC Copper Tape Shield 5kV

aislamiento de EPR
El forro de PVC
blindado
nivel de aislamiento 133%
ESPECIFICACIONES DE
1. CONDUCTOR: Clase B Trenzado, recocido, cobre desnudo según la norma ASTM B-3 y B-8, (trenzado compacto según la norma ASTM B-496 está disponible). escudo Strand es un extruido
termoestable semiconductora
2. AISLAMIENTO: Caucho de etileno propileno (EPR) por ICEA S-93-639 (NEMA WC74)
3. AISLAMIENTO SHIELD: extruido termoestable blindaje de aislamiento semiconductor. Escudo metálico es una cinta de cobre sin recubrimiento 5 mil aplicada helicoidalmente
4. CHAQUETA EN GENERAL: La luz solar resistente, negro cloruro de polivinilo (PVC)
5. NORMAS: engloban en el tipo MV-105 por UL 1072 y cumple con los requisitos de ICEA S-93-639. Tamaños 1/0 y mayor indicación «para uso de la TC» y pasar UL 1685 70.000 Btu / hr
prueba de la llama
6. AMPACIDAD: Sobre la base de tres cables conductores individuales aislados en el conducto de aire de acuerdo con la Tabla NEC 310.73 con una temperatura del conductor de 90 ° C y una temperatura ambiente de 40 ° C
7. Temperatura: 105 ° C
8. Voltaje: 5 kV 133% y 8 kV 100%
APLICACIONES
Para su uso en circuitos de potencia de hasta 8 kV cuando se instala en el aire abierto, conducto, conducto o enterrado directamente en la tierra, para lugares húmedos y secos. Se utiliza para aplicaciones de potencia en química
plantas, refinerías, fábricas de acero, plantas industriales, subestaciones y centrales eléctricas.

Los cables con trenzado compacto tienen diámetros totales ligeramente más pequeñas.
Diámetros y pesos pueden variar entre los fabricantes.

Power Cable EPR PVC Copper Tape Shield 5kV

EPR insulation
PVC jacket
Shielded
133% insulation level
SPECIFICATIONS OF
1. CONDUCTOR: Class B stranded, annealed, bare copper per ASTM B-3 and B-8, (compact stranding per ASTM B-496 is available). Strand shield is an extruded
semi-conducting thermoset
2. INSULATION: Ethylene Propylene Rubber (EPR) per ICEA S-93-639 (NEMA WC74)
3. INSULATION SHIELD: Extruded semi-conducting thermoset insulation shield. Metallic shield is a helically applied 5 mil uncoated copper tape
4. OVERALL JACKET: Sunlight-resistant, black Polyvinyl Chloride (PVC)
5. STANDARDS: Listed as Type MV-105 per UL 1072 and meets the requirements of ICEA S-93-639. Sizes 1/0 and larger marked «for CT use» and pass UL 1685 70,000 Btu/hr
flame test
6. AMPACITY: Based on three single conductor cables in isolated conduit in air per NEC Table 310.73 with a conductor temperature of 90°C and an ambient temperature of 40°C
7. TEMPERATURE: 105°C
8. VOLTAGE: 5 kV 133% and 8 kV 100%
APPLICATIONS
For use in power circuits up to 8 kV when installed in open air, conduit, duct or buried directly in the earth, for wet and dry locations. Used for power applications in chemical
plants, refineries, steel mills, industrial plants, utility substations and generating stations.

Cables with compact stranding have slightly smaller overall diameters.
Diameters and weights may vary among manufacturers.

3DA-0201, 3DA-1011, 3DA-2021, 3DA-4041, 3DA-2501, 3DA-3501, 3DA-5001, 3DA-7501, 3DA-10001

Power Cable EPR PVC Copper Tape Shield 5kV en: Tijuana, Rosarito, Mexicali, Ensenada, Tecate, San Luis Rio Colorado, Son, La Paz, BCS, Los Cabos BCS, Mexico

Etiquetado con: , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,
Publicado en: Cable y Alambre, Wire and Cable

Lead free EPR PVC Copper Tape Shield 5 kV

Lead free EPR PVC Copper Tape Shield 5 kV

Power Cable Lead free EPR PVC Copper Tape Shield 5 kV

Lead free EPR PVC Copper Tape Shield

3DA-0201-SW, 3DA-1011-SW, 3DA-2021-SW, 3DA-4041-SW, 3DA-2501-SW, 3DA-3501-SW, 3DA-5001-SW, 3DA-7501-SW, 3DA-10001-SW

Somos Especialistas en Cables. Distribuimos en toda la Republica Mexicana: Innovative Trade Center, Tel: (664) 621 33 36 / 621 30 09 ventas@innovative.com.mx, soporte@innovative.com.mx, Tijuana, B. C. www.innovative.com.mx

Power Cable Lead free EPR PVC Copper Tape Shield 5 kV

aislamiento de EPR
El forro de PVC
blindado
nivel de aislamiento 133%
Sin plomo
No se requiere lubricación
ESPECIFICACIONES DE
1. CONDUCTOR: Clase B Trenzado, recocido, cobre desnudo por ASTM B3 y B8, (trenzado compacto según la norma ASTM B-496 está disponible), el escudo es una hebra conductora extruida
compuesto termoestable
2. AISLAMIENTO: Caucho de etileno propileno (EPR) por ICEA S-93-639 (NEMA WC74)
3. blindaje de aislamiento: Durante el aislamiento es un semiconductor extruido, termoestable blindaje de aislamiento. Escudo metálico es una cinta de cobre sin recubrimiento 5 mil aplicada helicoidalmente
4. En general CHAQUETA: La luz solar resistente al negro instalación de cloruro de polivinilo (PVC), el cumplimiento de los requisitos de ICEA y UL 1072. Lubricante incorporado en la chaqueta para facilitar
5. NORMAS: engloban en el tipo MV-105 por UL 1072, cumple con los requisitos de ICEA S-93-639, tamaños 1/0 y más grande la indicación «para uso de la TC» y pasar UL 1685 70.000 Btu / hr
prueba de la llama
6. AMPACIDAD: Sobre la base de tres cables conductores individuales aislados en el conducto de aire de acuerdo con la Tabla NEC 310.73 con una temperatura del conductor de 90 ° C y una temperatura ambiente de 40 ° C
7. Temperatura: 105 ° C
8. Voltaje: 5 kV 133% y 8 kV 100%
APLICACIONES
Para su uso en circuitos de potencia de hasta 8 kV cuando se instala en el aire abierto, conducto, conducto o enterrado directamente en la tierra, para lugares húmedos y secos. Se utiliza para aplicaciones de potencia en química
plantas, refinerías, fábricas de acero, plantas industriales, subestaciones y estaciones generadoras ..

Los cables con trenzado compacto tienen diámetros totales ligeramente más pequeñas.
Diámetros y pesos pueden variar entre los fabricantes.

Power Cable Lead free EPR PVC Copper Tape Shield 5 kV

EPR insulation
PVC jacket
Shielded
133% insulation level
Lead-free
No lube required
SPECIFICATIONS OF
1. CONDUCTOR: Class B stranded, annealed, bare copper per ASTM B3 and B8, (compact stranding per ASTM B-496 is available), strand shield is an extruded conducting
thermosetting compound
2. INSULATION: Ethylene Propylene Rubber (EPR) per ICEA S-93-639 (NEMA WC74)
3. INSULATION SHIELD: Over the insulation is an extruded semi-conducting, thermosetting insulation shield. Metallic shield is a helically applied 5 mil uncoated copper tape
4. OVERALL JACKET: Sunlight-resistant black Polyvinyl Chloride (PVC), meeting the requirements of ICEA and UL 1072. Lubricant built into jacket to facilitate installation
5. STANDARDS: Listed as Type MV-105 per UL 1072, meets the requirements of ICEA S-93-639, sizes 1/0 and larger marked «for CT use» and pass UL 1685 70,000 Btu/hr
flame test
6. AMPACITY: Based on three single conductor cables in isolated conduit in air per NEC Table 310.73 with a conductor temperature of 90°C and an ambient temperature of 40°C
7. TEMPERATURE: 105°C
8. VOLTAGE: 5 kV 133% and 8 kV 100%
APPLICATIONS
For use in power circuits up to 8 kV when installed in open air, conduit, duct or buried directly in the earth, for wet and dry locations. Used for power applications in chemical
plants, refineries, steel mills, industrial plants, utility substations and generating stations..

Cables with compact stranding have slightly smaller overall diameters.
Diameters and weights may vary among manufacturers.

3DA-0201-SW, 3DA-1011-SW, 3DA-2021-SW, 3DA-4041-SW, 3DA-2501-SW, 3DA-3501-SW, 3DA-5001-SW, 3DA-7501-SW, 3DA-10001-SW

Power Cable Lead free EPR PVC Copper Tape Shield 5 kV en: Tijuana, Rosarito, Mexicali, Ensenada, Tecate, San Luis Rio Colorado, Son, La Paz, BCS, Los Cabos BCS, Mexico

Etiquetado con: , , , , , , , , , , , , , , , , , , , , , , , , , ,
Publicado en: Cable y Alambre, Wire and Cable

HERRAMIENTA DE COMPRESION CT 3001

HERRAMIENTA DE COMPRESION CT 3001

HERRAMIENTA DE COMPRESION CT 3001

CT 3001 CT-3001, CD-2001-F87, CD-2001-F89, CD-2001-F90, CD-2001-F91, CD-2001-F92, CD-2001-F93, CD-2001-F94, F87-18-C, F87-22-C, F87-25-C, F87-32-C, F89-25-L, F89-32-L, F90-25-L, F90-30-L, F90-32-L, F91-32-L, F91-40-L, F92-32-L, F92-38-L, F93-32-Q, F93-40-Q, F94-40-Q, FSD87-20-L, FSD87-25-Q, FSD89-20-Q, FSD89-27-Q, FSD90-25-Q, FSD91-27-Q, FSD92-32-Q

HERRAMIENTA DE COMPRESION CT 3001

Contactanos en www.innovative.com.mx,  Tel: (664) 621 30 09 / 621 37 36, ventas@innovative.com.mx,  INNOVATIVE TRADE CENTER, Tijuana, Baja California, soporte@innovative.com.mx

Herramienta de prensa con tecnología hidráulica, 6 toneladas para terminales tipo zapata o de compresión

CT-1301 2

CARACRERISICAS HERRAMIENTA DE COMPRESION CT 3001

• Batería de litio-ion de potencia, proporciona un funcionamiento y hasta la punta del dedo
90% más de ciclos por carga de la batería que las herramientas alimentadas con baterías de NiCd o baterías NiMH
• En línea con el diseño de la herramienta de perfil bajo, de 180 ° de rotación, de presión cerrado, diseño de la cabeza para llegar a espacios reducidos
• Ligero y ergonómico equilibrado para un funcionamiento sencillo y sin fatiga, pesa 7,15 lbs. con la batería
• Unidad autónoma, completamente portátil
• Desarrolla 6 toneladas de fuerza de presión, hasta 389 ciclos por la batería para terminales de cobre y empalmes kcmil
• Certificados UL y CSA de la HERRAMIENTA DE COMPRESION CT 3001
• Audible válvula «pop-off», indica la finalización de la presión
• Herramienta provista de dos baterías recargables, de alta capacidad de Milwaukee M18 XC de iones de litio 18 VCC, cargador de baterías correa para la muñeca y bolsa para herramienta
• Medidor de carga de baterías, incorporada con LED por lo que el nivel de carga
• Aproximadamente 2,9 segundos del tiempo de ciclo de presión ofrece una rápida terminaciones, 26% más rápido que con las herramientas de NiCd o NiMH
• Los costos de cargador de baterías gastadas las pilas por completo en 30-60 minutos
• Compatible con CD-2001 y engarzado con código de color CDM-2001, para facilitar el juego de presión del conector con la HERRAMIENTA DE COMPRESION CT 3001
• estampa el número de índice de barriles del conector para proporcionar el poste
inspección
• Dado instalado, usando pasadores de retención por resorte, no hay necesidad de otra herramientas

CT-1301 4CT-1301 5

HERRAMIENTA DE COMPRESION CT 3001 CT 3001 en San Luis Rio Colorado, Mexicali, Tecate, Tijuana, Rosarito, Ensenada, La Paz, Los Cabos

N.P. de la HERRAMIENTA DE COMPRESION CT 3001 CT-3001, CD-2001-F87, CD-2001-F89, CD-2001-F90, CD-2001-F91, CD-2001-F92, CD-2001-F93, CD-2001-F94, F87-18-C, F87-22-C, F87-25-C, F87-32-C, F89-25-L, F89-32-L, F90-25-L, F90-30-L, F90-32-L, F91-32-L, F91-40-L, F92-32-L, F92-38-L, F93-32-Q, F93-40-Q, F94-40-Q, FSD87-20-L, FSD87-25-Q, FSD89-20-Q, FSD89-27-Q, FSD90-25-Q, FSD91-27-Q, FSD92-32-Q

Etiquetado con: , , , , , , , , , , , , , , , , , , , , , , , , ,
Publicado en: Soluciones

EPR CPE Unishield

EPR CPE Unishield

Power Cable EPR CPE Unishield

EPR CPE Unishield

3USA-0201, 3USA-1011, 3USA-2021, 3USA-4041, 3USA-2501, 3USA-3501, 3USA-5001, 3USA-7501, 3USA-10001

Somos Especialistas en Cables. Distribuimos en toda la Republica Mexicana: Innovative Trade Center, Tel: (664) 621 33 36 / 621 30 09 ventas@innovative.com.mx, soporte@innovative.com.mx, Tijuana, B. C. www.innovative.com.mx

Power Cable EPR CPE Unishield

aislamiento de EPR
chaqueta de CPE
blindado
nivel de aislamiento 133%
Especificaciones de
1. CONDUCTOR: Clase B de trenzado compacto, de cobre desnudo recocido según la norma ASTM B-3 y B-496, escudo cadena es un compuesto semiconductor extruido
2. AISLAMIENTO: Caucho de etileno propileno (EPR) por ICEA S-93-639 (NEMA WC74)
3. SISTEMA DE SHIELD: Combinación de seis hilos de drenaje de cobre y polietileno clorado semiconductora extruida (CPE)
4. NORMAS: Listado Tipo MV-105 por UL 1072. Cumple los requisitos de ICEA S-93-639 / NEMA WC74. Pasa IEEE 1202 (70.000 Btu / hr) / CSA FT4. Tamaños 1/0 y más grandes marcada
La luz del sol pasar Resistentes a UL 1685 de 70.000 BTU ensayo a la llama / hr y se califican «para el uso de CT» UL
5. AMPACIDAD: Sobre la base de tres cables conductores individuales aislados en el conducto de aire de acuerdo con la Tabla NEC 310.73 con una temperatura del conductor de 90 ° C y una temperatura ambiente de 40 ° C
6. Temperatura: 105 ° C
7. Voltaje: 5 kV
APLICACIONES
Para su uso en circuitos de potencia de hasta 5 kV cuando se instala en el aire abierto, conducto, conductos, o enterrado directamente en la tierra, para lugares húmedos y secos. Se utiliza para aplicaciones de potencia en química
plantas, refinerías, fábricas de acero, plantas industriales, subestaciones y centrales eléctricas

Power Cable EPR CPE Unishield

EPR insulation
CPE jacket
Shielded
133% insulation level
SPECIFICATIONS of
1. CONDUCTOR: Class B compact stranded, annealed bare copper per ASTM B-3 and B-496, strand shield is an extruded semiconducting compound
2. INSULATION: Ethylene Propylene Rubber (EPR) per ICEA S-93-639 (NEMA WC74)
3. SHIELD SYSTEM: Combination of six copper drain wires and extruded semiconducting Chlorinated Polyethylene (CPE) jacket
4. STANDARDS: Listed Type MV-105 per UL 1072. Meets requirements of ICEA S-93-639 / NEMA WC74. Passes IEEE 1202 (70,000 Btu/hr)/CSA FT4. Sizes 1/0 and larger marked
Sunlight Resistant and pass UL 1685 70,000 Btu/hr flame test and are UL rated «for CT use»
5. AMPACITY: Based on three single conductor cables in isolated conduit in air per NEC Table 310.73 with a conductor temperature of 90°C and an ambient temperature of 40°C
6. TEMPERATURE: 105°C
7. VOLTAGE: 5 kV
APPLICATIONS
For use in power circuits up to 5 kV when installed in open air, conduit, duct, or buried direct in earth, for wet and dry locations. Used for power applications in chemical
plants, refineries, steel mills, industrial plants, utility substations and generating stations

3USA-0201, 3USA-1011, 3USA-2021, 3USA-4041, 3USA-2501, 3USA-3501, 3USA-5001, 3USA-7501, 3USA-10001

Power Cable EPR CPE Unishield en: Tijuana, Rosarito, Mexicali, Ensenada, Tecate, San Luis Rio Colorado, Son, La Paz, BCS, Los Cabos BCS, Mexico

Etiquetado con: , , , , , , , , , , , , , , , , , , , , , , , , , , ,
Publicado en: Cable y Alambre, Wire and Cable

EPR CPE CSPE

EPR CPE CSPE

Power Cable EPR CPE CSPE

EPR CPE CSPE

3DC-0601, 3DC-0401, 3DC-0201, 3DC-1011, 3DC-2021, 3DC-3031, 3DC-4041, 3DC-2501, 3DC-3501, 3DC-5001, 3DC-7501, 3DC-10001

Somos Especialistas en Cables. Distribuimos en toda la Republica Mexicana: Innovative Trade Center, Tel: (664) 621 33 36 / 621 30 09 ventas@innovative.com.mx, soporte@innovative.com.mx, Tijuana, B. C. www.innovative.com.mx

Power Cable EPR CPE CSPE

aislamiento de EPR
CPE o chaqueta CSPE
no apantallado
Listado UL Tipo MV-90
PRESUPUESTO
1. CONDUCTOR: Clase B Trenzado, recocido, cobre desnudo según la norma ASTM B-3 y B-8, escudo cadena es un compuesto semiconductor extruido por ICEA S-96-659 (NEMA WC71)
2. AISLAMIENTO: Caucho de etileno propileno (EPR), que cumple o excede ICEA S-96-659 y UL 1072. Para lugares húmedos o secos por UL 1072 y NEC artículo 328
3. CHAQUETA EN GENERAL: CPE o CSPE
4. NORMAS: Listado Tipo MV-90 por UL 1072 para lugares húmedos y secos. Cumple con los requisitos de ICEA S-96-659 (NEMA WC71). Tamaños 1/0 y mayor luz del sol marcada Resistentes
IEEE pasar la prueba de la llama 383 70.000 Btu / hr y están marcados «para uso TC»
5. AMPACIDAD: Sobre la base de tres cables conductores individuales aislados en el conducto de aire de acuerdo con la Tabla NEC 310.73 con una temperatura del conductor de 90 ° C y una temperatura ambiente de 40 ° C
6. Temperatura: 90 ° C
7. TENSION: 2.400 V
APLICACIONES
Para su uso en circuitos de potencia de hasta 2.400 V en la que los escudos no pueden ser debidamente terminados y donde el espacio es limitado. Cable se utiliza para aplicaciones de energía en plantas químicas,
refinerías, fábricas de acero, plantas industriales, subestaciones y centrales eléctricas. Es ideal para aplicaciones donde se requiere una mayor durabilidad.

Diámetros y pesos pueden variar entre los fabricantes.

Power Cable EPR CPE CSPE

EPR insulation
CPE or CSPE jacket
Nonshielded
UL Listed Type MV-90
SPECIFICATIONS
1. CONDUCTOR: Class B stranded, annealed, bare copper per ASTM B-3 and B-8, strand shield is an extruded semiconducting compound per ICEA S-96-659 (NEMA WC71)
2. INSULATION: Ethylene Propylene Rubber (EPR) which meets or exceeds ICEA S-96-659 and UL 1072. For wet or dry locations per UL 1072 and NEC Article 328
3. OVERALL JACKET: CPE or CSPE
4. STANDARDS: Listed Type MV-90 per UL 1072 for wet and dry locations. Meets requirements of ICEA S-96-659 (NEMA WC71). Sizes 1/0 and larger marked Sunlight Resistant and
pass IEEE 383 70,000 Btu/hr flame test and are marked «for CT use»
5. AMPACITY: Based on three single conductor cables in isolated conduit in air per NEC Table 310.73 with a conductor temperature of 90°C and an ambient temperature of 40°C
6. TEMPERATURE: 90°C
7. VOLTAGE: 2,400 V
APPLICATIONS
For use in power circuits up to 2,400 V where shields cannot be properly terminated and where space is limited. Cable is used for power applications in chemical plants,
refineries, steel mills, industrial plants, utility substations and generating stations. Ideally suited for applications where increased durability is required.

Diameters and weights may vary among manufacturers.

3DC-0601, 3DC-0401, 3DC-0201, 3DC-1011, 3DC-2021, 3DC-3031, 3DC-4041, 3DC-2501, 3DC-3501, 3DC-5001, 3DC-7501, 3DC-10001

Power Cable EPR CPE CSPE en: Tijuana, Rosarito, Mexicali, Ensenada, Tecate, San Luis Rio Colorado, Son, La Paz, BCS, Los Cabos BCS, Mexico

Etiquetado con: , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,
Publicado en: Cable y Alambre, Wire and Cable

XLP USE 2 CT Rated

XLP USE 2 CT Rated

Power Cable XLP USE 2 CT Rated

XLP USE 2 CT Rated

3B-1011-CT-02, 3B-2021-CT-02, 3B-3031-CT-02, 3B-4041-CT-02, 3B-2501-CT-02, 3B-3501-CT-02, 3B-5001-CT-02, 3B-7501-CT-02, 3B-10001-CT-02

Somos Especialistas en Cables. Distribuimos en toda la Republica Mexicana: Innovative Trade Center, Tel: (664) 621 33 36 / 621 30 09 ventas@innovative.com.mx, soporte@innovative.com.mx, Tijuana, B. C. www.innovative.com.mx

Power Cable XLP USE 2 CT Rated

XLP
90 ° C húmedo / seco
Lista UL para uso de la TC
ESPECIFICACIONES
1. CONDUCTOR: trenzado de Clase B, recocido, cobre desnudo según la norma ASTM B-8
2. Aislamiento: Polietileno reticulado (XLP) por ICEA S-95-658 (NEMA WC70)
3. NORMAS: Cable aparece como tipo USE-2 por UL 854 y RHH / RHW-2 por UL 44. Calificación «para el uso de la TC» y pasa el IEEE 383 y IEEE 1202 / CSA FT-4 ensayos a la llama
4. AMPACIDAD: Basado en no más de tres conductores en la pista de rodadura cable o tierra según NEC 310.16 con una temperatura ambiente de 30 ° C
5. Temperatura: 90 ° C
6. VOLTAJE: 600 V
APLICACIONES
cableado de propósito general para los circuitos de control, centralita telefónica, alumbrado y fuerza en los edificios residenciales y comerciales, plantas industriales, así como para las subestaciones de servicios públicos y
plantas de generación

Power Cable XLP USE 2 CT Rated

XLP
90°C wet/dry
UL Listed for CT use
SPECIFICATIONS
1. CONDUCTOR: Class B stranding, annealed, bare copper per ASTM B-8
2. INSULATION: Cross-Linked Polyethylene (XLP) per ICEA S-95-658 (NEMA WC70)
3. STANDARDS: Cable is listed as Type USE-2 per UL 854 and RHH/RHW-2 per UL 44. Rated «for CT use» and passes the IEEE 383 and IEEE 1202/CSA FT-4 flame tests
4. AMPACITY: Based on not more than three conductors in raceway or cable or earth per NEC 310.16 with an ambient temperature of 30°C
5. TEMPERATURE: 90°C
6. VOLTAGE: 600 V
APPLICATIONS
General purpose wiring for control, switchboard, lighting and power circuits in residential and commercial buildings, industrial plants as well as for utility substations and
generating plants.

3B-1011-CT-02, 3B-2021-CT-02, 3B-3031-CT-02, 3B-4041-CT-02, 3B-2501-CT-02, 3B-3501-CT-02, 3B-5001-CT-02, 3B-7501-CT-02, 3B-10001-CT-02

Power Cable XLP USE 2 CT Rated en: Tijuana, Rosarito, Mexicali, Ensenada, Tecate, San Luis Rio Colorado, Son, La Paz, BCS, Los Cabos BCS, Mexico

Etiquetado con: , , , , , , , , , , , , , , , , , , , , , , ,
Publicado en: Cable y Alambre, Wire and Cable

HERRAMIENTA DE CRIMPEO CT 3001

HERRAMIENTA DE CRIMPEO CT 3001

HERRAMIENTA DE CRIMPEO CT 3001

CT-3001, CD-2001-F87, CD-2001-F89, CD-2001-F90, CD-2001-F91, CD-2001-F92, CD-2001-F93, CD-2001-F94, F87-18-C, F87-22-C, F87-25-C, F87-32-C, F89-25-L, F89-32-L, F90-25-L, F90-30-L, F90-32-L, F91-32-L, F91-40-L, F92-32-L, F92-38-L, F93-32-Q, F93-40-Q, F94-40-Q, FSD87-20-L, FSD87-25-Q, FSD89-20-Q, FSD89-27-Q, FSD90-25-Q, FSD91-27-Q, FSD92-32-Q

HERRAMIENTA DE CRIMPEO CT 3001

Contactanos en www.innovative.com.mx,  Tel: (664) 621 30 09 / 621 37 36, ventas@innovative.com.mx,  INNOVATIVE TRADE CENTER, Tijuana, Baja California, soporte@innovative.com.mx

Herramienta de prensa con tecnología hidráulica, 6 toneladas para terminales tipo zapata o de compresión

CT-1301 2

CARACRERISICAS HERRAMIENTA DE CRIMPEO CT 3001

• Batería de litio-ion de potencia, proporciona un funcionamiento y hasta la punta del dedo
90% más de ciclos por carga de la batería que las herramientas alimentadas con baterías de NiCd o baterías NiMH
• En línea con el diseño de la herramienta de perfil bajo, de 180 ° de rotación, de presión cerrado, diseño de la cabeza para llegar a espacios reducidos
• Ligero y ergonómico equilibrado para un funcionamiento sencillo y sin fatiga, pesa 7,15 lbs. con la batería
• Unidad autónoma, completamente portátil
• Desarrolla 6 toneladas de fuerza de presión, hasta 389 ciclos por la batería para terminales de cobre y empalmes kcmil
• Certificados UL y CSA de la HERRAMIENTA DE CRIMPEO CT 3001
• Audible válvula «pop-off», indica la finalización de la presión
• Herramienta provista de dos baterías recargables, de alta capacidad de Milwaukee M18 XC de iones de litio 18 VCC, cargador de baterías correa para la muñeca y bolsa para herramienta
• Medidor de carga de baterías, incorporada con LED por lo que el nivel de carga
• Aproximadamente 2,9 segundos del tiempo de ciclo de presión ofrece una rápida terminaciones, 26% más rápido que con las herramientas de NiCd o NiMH
• Los costos de cargador de baterías gastadas las pilas por completo en 30-60 minutos
• Compatible con CD-2001 y engarzado con código de color CDM-2001, para facilitar el juego de presión del conector con la HERRAMIENTA DE CRIMPEO CT 3001
• estampa el número de índice de barriles del conector para proporcionar el poste
inspección
• Dado instalado, usando pasadores de retención por resorte, no hay necesidad de otra herramientas

CT-1301 4CT-1301 5

HERRAMIENTA DE CRIMPEO CT 3001 en San Luis Rio Colorado, Mexicali, Tecate, Tijuana, Rosarito, Ensenada, La Paz, Los Cabos

N.P. de la HERRAMIENTA DE CRIMPEO CT-3001, CD-2001-F87, CD-2001-F89, CD-2001-F90, CD-2001-F91, CD-2001-F92, CD-2001-F93, CD-2001-F94, F87-18-C, F87-22-C, F87-25-C, F87-32-C, F89-25-L, F89-32-L, F90-25-L, F90-30-L, F90-32-L, F91-32-L, F91-40-L, F92-32-L, F92-38-L, F93-32-Q, F93-40-Q, F94-40-Q, FSD87-20-L, FSD87-25-Q, FSD89-20-Q, FSD89-27-Q, FSD90-25-Q, FSD91-27-Q, FSD92-32-Q

Etiquetado con: , , , , , , , , , , , , , , , , , , , , , , ,
Publicado en: Panduit Electrico, Soluciones
Descarga Aquí este Catálogo
Archivos
Subscribase a este sitio