20 10 Substation Control Cable

20 10 Substation Control Cable

Control Cable 20 10 Substation Control Cable

20 10 Substation Control Cable

1402, 1403, 1404, 1405, 1407, 1409, 1410, 1412, 1414, 1415, 1419, 1425, 1430, 1437, 1202, 1203, 1204, 1205, 1207, 1208, 1212, 1215, 1219, 1225, 1237, 1002, 1003, 1004, 1005, 1007, 1008, 1009, 1012, 0902, 0903, 0904, 0905, 0907, 0909

Somos Especialistas en Cables. Distribuimos en toda la Republica Mexicana: Innovative Trade Center, Tel: (664) 621 33 36 / 621 30 09 ventas@innovative.com.mx, soporte@innovative.com.mx, Tijuana, B. C. www.innovative.com.mx

Control Cable 20 10 Substation Control Cable

aislamiento de polietileno y PVC
El forro de PVC
75 ° C, 600 V
ESPECIFICACIONES
1. CONDUCTORES: Cobre desnudo recocido blando según la norma ASTM B-3, los conductores son de clase B hebra concéntrica de acuerdo con la norma ASTM B-8
2. AISLAMIENTO: 20 milésimas de pulgada de polietileno de alto peso molecular (HMWPE), cubierto con 10 milésimas de pulgada de un código de colores de cloruro de polivinilo (PVC)
3. CÓDIGO DE COLORES: ICEA Método 1, Tabla E-1 (antes de K-1)
4. Montaje: Aislado conductores están cableados con rellenos como sea necesario, las construcciones de dos conductores son planas, todos los demás completan
5. CHAQUETA EN GENERAL: Policloruro de vinilo compuesto (PVC), el cumplimiento de los requisitos de ICEA S-73-532 (NEMA WC57)
6. NORMAS: cable acabado cumple ICEA S-73-532 (NEMA WC57)
7. Temperatura: 75ºC
8. Voltaje: 600 V
APLICACIONES
Para su uso en circuitos de control para subestaciones de servicios públicos, y varios de funcionamiento, retransmisión, telemedida, indicando, de señalización y circuitos de medición para las plantas industriales y
procesos. Adecuado para su empleo en tuberías, conductos y aérea.

Control Cable 20 10 Substation Control Cable

Polyethylene-PVC insulation
PVC jacket
75°C, 600 V
SPECIFICATIONS
1. CONDUCTORS: Bare soft annealed copper per ASTM B-3, conductors are Class B concentric strand in accordance with ASTM B-8
2. INSULATION: 20 mils of high molecular weight polyethylene (HMWPE), covered with 10 mils of color-coded Polyvinyl Chloride (PVC)
3. COLOR CODE: ICEA Method 1, Table E-1 (formerly K-1)
4. ASSEMBLY: Insulated conductors are cabled with fillers as necessary, the two-conductor constructions are flat, all others round
5. OVERALL JACKET: Polyvinyl Chloride (PVC) compound, meeting the requirements of ICEA S-73-532 (NEMA WC57)
6. STANDARDS: Finished cable meets ICEA S-73-532 (NEMA WC57)
7. TEMPERATURE: 75ºC
8. VOLTAGE: 600 V
APPLICATIONS
For use in control circuits for utility substations, and various operating, relaying, telemetering, indicating, signalling and measuring circuits for industrial plants and
processes. Suitable for use in duct, conduit and aerial.

2B-1402, 2B-1403, 2B-1404, 2B-1405, 2B-1407, 2B-1409, 2B-1410, 2B-1412, 2B-1414, 2B-1415, B-1419, B-1425, B-1430, 2B-1437, 2B-1202, 2B-1203, 2B-1204, 2B-1205, 2B-1207, 2B-1208, 2B-1212, 2B-1215, 2B-1219, 2B-1225, 2B-1237, 2B-1002, 2B-1003, 2B-1004,2B-1005, 2B-1007, 2B-1008, 2B-1009, 2B-1012, 2B-0902, 2B-0903, 2B-0904, 2B-0905, 2B-0907, 2B-0909

Control Cable 20 10 Substation Control Cable en: Tijuana, Rosarito, Mexicali, Ensenada, Tecate, San Luis Rio Colorado, Son, La Paz, BCS, Los Cabos BCS, Mexico

Etiquetado con: , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,
Publicado en: Cable y Alambre, Wire and Cable

Deja una respuesta

Tu dirección de correo electrónico no será publicada. Los campos obligatorios están marcados con *

*

Descarga Aquí este Catálogo
Subscribase a este sitio