5kV Single Conductor Nonshielded

5kV Single Conductor Nonshielded

Armored Cable 5kV Single Conductor Nonshielded

5kV Single Conductor Nonshielded

7TM-0601AJ, 7TM-0401AJ, 7TM-0201AJ, 7TM-0101AJ, 7TM-1011AJ, 7TM-2021AJ, 7TM-3031AJ, 7TM-4041AJ, 7TM-2501AJ, 7TM-3001AJ, 7TM-3501AJ, 7TM-4001AJ, 7TM-5001AJ, 7TM-6001AJ, 7TM-7501AJ, 7TM-10001AJ

Somos Especialistas en Cables. Distribuimos en toda la Republica Mexicana: Innovative Trade Center, Tel: (664) 621 33 36 / 621 30 09 ventas@innovative.com.mx, soporte@innovative.com.mx, Tijuana, B. C. www.innovative.com.mx

Armored Cable 5kV Single Conductor Nonshielded

Aluminio armadura entrelazada
aislamiento XLP
Las fundas de PVC interior y exterior
nivel de aislamiento 100% o 133%
PRESUPUESTO
1. CONDUCTOR: Clase B Trenzado, desnudo de cobre, suave
2. conductor de la pantalla: Los cables tienen un blindaje semiconductora sobre el conductor
3. Aislamiento: Polietileno reticulado (XLP), 90 milésimas de pulgada de espesor de aislamiento
4. Conductor de Tierra: Compuesto de hilos individuales aplicada helicoidalmente sobre el aislamiento
5. chaqueta interior: cloruro de polivinilo (PVC)
6. Armadura: Aluminio-enclavamiento armadura (para cables de un solo conductor para su uso en circuitos de corriente alterna sólo se facilita una armadura de aluminio y no magnéticas [] de aluminio y conectores de bloqueo
frutos secos deben ser usados)
7. Cubierta exterior: Policloruro de vinilo (PVC) al calor, a las llamas y una chaqueta resistente a la humedad, nominal -40 ° C, el color estándar es de color naranja, pero las chaquetas de colores están disponibles bajo petición
8. NORMAS: El cable está autorizado a CSA C22.2 No. 131 y No. 174 para su uso en CSA Clase 1, División 1, lugares peligrosos (CSA HL nominal) y pasa a la bandeja vertical de T4L
prueba de la llama
9. AMPACIDAD: Basado en 90 ° C la columna de la Tabla 1 del Código Eléctrico Canadiense de 2009, ampacidades permisibles para conductores de cobre individuales en el aire libre sobre la base de 30 ° C
temperatura ambiente
10.TEMPERATURE: -40 ° C a 90 ° C
11.VOLTAGE: 5 kV
APLICACIONES
Para expuesta u oculta el cableado en lugares húmedos o secos. Para su uso en ventilado de transporte por cable flexible, no ventilado y canales de cable tipo escalera y ventilado en húmedo o en seco
ubicaciones. Para el entierro directo

Nota: El cable blindado disponible.
Diámetros y pesos pueden variar entre los fabricantes

Armored Cable 5kV Single Conductor Nonshielded

Aluminum interlocked armor
XLP insulation
Inner and outer PVC jackets
100% or 133% insulation level
SPECIFICATIONS
1. CONDUCTOR: Class B stranded, bare, soft copper
2. CONDUCTOR SHIELD: Cables have a semiconducting shield over the conductor
3. INSULATION: Cross-Linked Polyethylene (XLP), 90 mils insulation thickness
4. GROUNDING CONDUCTOR: Composed of individual wires applied helically over the insulation
5. INNER JACKET: Polyvinyl Chloride (PVC)
6. ARMOR: Aluminum-interlocking armor (for single conductor cables for use in AC circuits only aluminum armor is provided and non-magnetic [aluminum] connectors and lock
nuts must be used)
7. OUTER JACKET: Polyvinyl Chloride (PVC) heat-, flame- and moisture-resistant jacket, rated -40°C, the standard color is orange but colored jackets are available on request
8. STANDARDS: The cable is certified to CSA C22.2 No. 131 and No. 174 for use in CSA Class 1, Division 1, hazardous locations (CSA HL rated) and passes the FT4 vertical tray
flame test
9. AMPACITY: Based on 90°C column of Table 1 of the 2009 Canadian Electric Code, allowable ampacities for single copper conductors in free air based on 30°C
ambient temperature
10.TEMPERATURE: -40°C to 90°C
11.VOLTAGE: 5 kV
APPLICATIONS
For exposed or concealed wiring in wet or dry locations. For use in ventilated, non-ventilated and ladder type cable troughs and ventilated flexible cableway in wet or dry
locations. For direct earth burial

Note: Shielded cable available.
Diameters and weights may vary among manufacturers

7TM-0601AJ, 7TM-0401AJ, 7TM-0201AJ, 7TM-0101AJ, 7TM-1011AJ, 7TM-2021AJ, 7TM-3031AJ, 7TM-4041AJ, 7TM-2501AJ, 7TM-3001AJ, 7TM-3501AJ, 7TM-4001AJ, 7TM-5001AJ, 7TM-6001AJ, 7TM-7501AJ, 7TM-10001AJ

Armored Cable 5kV Single Conductor Nonshielded en: Tijuana, Rosarito, Mexicali, Ensenada, Tecate, San Luis Rio Colorado, Son, La Paz, BCS, Los Cabos BCS, Mexico

Etiquetado con: , , , , , , , , , , , , , , , , , , , , , ,
Publicado en: Cable y Alambre, Wire and Cable

Deja una respuesta

Tu dirección de correo electrónico no será publicada. Los campos obligatorios están marcados con *

*

Descarga Aquí este Catálogo
Subscribase a este sitio