Individual Overall Shielded Multitriad

Individual Overall Shielded Multitriad

Control Cable Individual Overall Shielded Multitriad

Individual Overall Shielded Multitriad

323-331-2004, 323-331-2008, 323-331-2012, 323-331-2016, 323-331-2024, 323-331-2036, 323-331-1804, 323-331-1808, 323-331-1812, 323-331-1816, 323-331-1824, 323-331-1836, 323-331-1604, 323-331-1612

Somos Especialistas en Cables. Distribuimos en toda la Republica Mexicana: Innovative Trade Center, Tel: (664) 621 33 36 / 621 30 09 ventas@innovative.com.mx, soporte@innovative.com.mx, Tijuana, B. C. www.innovative.com.mx

Control Cable Individual Overall Shielded Multitriad

aislamiento de PVC
El forro de PVC
105 ° C, 300 V
Especificaciones de
1. CONDUCTORES: cobre desnudo, Clase B, concéntrico
2. AISLAMIENTO: 105 ° C cloruro de polivinilo (PVC)
3. TRÍADAS: Cada tríada está retorcido con un laico idóneo para reducir la interferencia magnética y código de color negro, cada tríada también se imprime numéricamente para asegurar la identificación fácil, una
Se aplica el blindaje de aluminio / poliéster con conductor de drenaje de cobre estañado trenzado
4. MONTAJE: Las tríadas individuales están cableados entre sí para formar una sección transversal sustancialmente circular del conjunto completo, un escudo de papel de aluminio / poliéster con hebra
hilo de drenaje de cobre estañado se aplica en general
5. En general CHAQUETA: retardante de llama,, negro cloruro de polivinilo (PVC) resistente a la luz solar
6. NORMAS: Cumple con el artículo 725 del NEC para el tipo PLTC y UL 13, cable acabado cumple con IEEE 1202 y UL 1685 ensayos a la llama de bandejas verticales
7. Temperatura: 105 ° C
8. Voltaje: 300 V
APLICACIONES
Para su uso como cable de instrumentación dentro o fuera en aplicaciones de control. Conveniente para la instalación en bandejas, cubetas, canales, conductos, canaletas y para uso aéreo cuando
con el apoyo de un mensajero. Adecuado para la clase 2 y 3 circuitos eléctricos por NEC artículo 725

Control Cable Individual Overall Shielded Multitriad

PVC insulation
PVC jacket
105°C, 300 V
SPECIFICATIONS of
1. CONDUCTORS: Bare copper, Class B, concentric stranded
2. INSULATION: 105°C Polyvinyl Chloride (PVC)
3. TRIADS: Each triad is twisted with a suitable lay to reduce magnetic interference and color coded black, each triad is also printed numerically to ensure easy identification, an
aluminum/polyester foil shield with stranded tinned copper drain wire is applied
4. ASSEMBLY: The individual triads are cabled together to form a substantially circular cross-section of the completed assembly, an aluminum/polyester foil shield with stranded
tinned copper drain wire is applied overall
5. OVERALL JACKET: Flame-retardant, sunlight-resistant, black Polyvinyl Chloride (PVC) jacket
6. STANDARDS: Meets Article 725 of the NEC for Type PLTC and UL 13, finished cable meets IEEE 1202 and UL 1685 vertical tray flame tests
7. TEMPERATURE: 105°C
8. VOLTAGE: 300 V
APPLICATIONS
For use as instrumentation cable inside or outside in control applications. Suitable for installation in trays, troughs, channels, conduit, wireways and for aerial use when
supported by a messenger. Suitable for Class 2 and 3 electrical circuits per NEC Article 725.

323-331-2004, 323-331-2008, 323-331-2012, 323-331-2016, 323-331-2024, 323-331-2036, 323-331-1804, 323-331-1808, 323-331-1812, 323-331-1816, 323-331-1824, 323-331-1836, 323-331-1604, 323-331-1612

Control Cable Individual Overall Shielded Multitriad en: Tijuana, Rosarito, Mexicali, Ensenada, Tecate, San Luis Rio Colorado, Son, La Paz, BCS, Los Cabos BCS, Mexico

Etiquetado con: , , , , , , , , , , , , , , , , , , , , ,
Publicado en: Cable y Alambre, Wire and Cable

Deja una respuesta

Tu dirección de correo electrónico no será publicada. Los campos obligatorios están marcados con *

*

Descarga Aquí este Catálogo