RHH ST1 KS24194 L3

RHH ST1 KS24194 L3

Power Cable RHH ST1 KS24194 L3

RHH ST1 KS24194 L3

3BAL-1401-XX, 3BAL-1201-XX, 3BAL-1001-XX, 3BAL-0801-XX, 3BAL-0601-XX, 3BAL-0401-XX, 3BAL-0201-XX, 3BAL-1011-XX, 3BAL-2021-XX, 3BAL-4041-XX, 3BAL-3501-XX, 3BAL-5001-XX, 3BAL-7501-XX

Somos Especialistas en Cables. Distribuimos en toda la Republica Mexicana: Innovative Trade Center, Tel: (664) 621 33 36 / 621 30 09 ventas@innovative.com.mx, soporte@innovative.com.mx, Tijuana, B. C. www.innovative.com.mx

Power Cable RHH ST1 KS24194 L3

trenza de algodón
600 V
105 ° C en seco, en húmedo 60 ° C
PRESUPUESTO
1. CONDUCTOR: Clase B de cobre estañado trenzado conforme a ASTM B-8, los requisitos de UL B-33 y, a través de los tamaños de 14 AWG 750 kcmil
2. AISLAMIENTO: 105 ° C puntuación humo limitado, libre de halógenos TelcoHyde 5221 conforme a las normas UL 44, 758 Temas 509 y CSA C22.2 No.210.2 M90, además,
TelcoHyde 5221 cumple con los requisitos de Telcordia Especificación GR-347-CORE, el aislamiento tiene un Índice límite de oxígeno de 35%
3. CARACTERÍSTICAS: Una cinta de aluminio / poliéster opaca se aplicarán sobre el conductor para facilitar la extracción, el humo limitado, no halogenado con aislamiento
4. NORMAS: UL Listed RHH / LS con trenza de algodón y VW-1 UL Listed «para el uso de la TC» (1/0 y más grande) CSA para la prueba de la llama / humo / ST1 T4 libre, libre de plomo y libre de silicona, se reúne
Directiva europea RoHS, cumple con Telcordia GR-347-CORE
5. Temperatura: 105 ° C en seco, en húmedo 60 ° C
6. VOLTAJE: 600 V, FT4, ST1
APLICACIONES
cable de transmisión de telecomunicaciones. Los cables están diseñados para su uso en circuitos de 600 V CA o CC en las telecomunicaciones oficinas centrales, sitios inalámbricos, estaciones repetidoras, datos
y otros centros de UPS y sistemas de administración de energía. El cable puede ser instalado en bandejas, bastidores, o conducto en aplicaciones horizontales y verticales.

Todos los números de referencia requieren designación del código de color.
Vea la tabla de código de color

Power Cable RHH ST1 KS24194 L3

Cotton braid
600 V
105°C dry, 60°C wet
SPECIFICATIONS
1. CONDUCTOR: Class B stranded tin-coated copper conforming to ASTM B-8, B-33 and UL requirements, sizes 14 AWG thru 750 kcmil
2. INSULATION: 105°C rated limited smoke, zero halogen TelcoHyde 5221 conforming to UL Standards 44, 758 Subjects 509 and CSA C22.2 No.210.2 M90, in addition,
TelcoHyde 5221 complies with the requirements of Telcordia Specification GR-347-CORE, the insulation has a Limiting Oxygen Index of 35%
3. FEATURES: An opaque aluminum/polyester tape shall be applied over the conductor to facilitate stripping, limited smoke, non-halogenated insulated
4. STANDARDS: UL Listed RHH/LS with cotton braid and VW-1 UL Listed «for CT use» (1/0 and larger) CSA for the FT4/ST1 flame/smoke test, lead-free and silicone free, meets
European RoHS directive, complies with Telcordia GR-347-CORE
5. TEMPERATURE: 105°C dry, 60°C wet
6. VOLTAGE: 600 V, FT4, ST1
APPLICATIONS
Telecommunications power cable. The cables are designed for use in 600 V AC or DC circuits in telecommunications central offices, wireless sites, repeater stations, data
centers and other UPS and power management systems. The cable can be installed in trays, racks, or conduit in horizontal and vertical applications.

All part numbers require color code designation.
See Color Code chart

3BAL-1401-XX, 3BAL-1201-XX, 3BAL-1001-XX, 3BAL-0801-XX, 3BAL-0601-XX, 3BAL-0401-XX, 3BAL-0201-XX, 3BAL-1011-XX, 3BAL-2021-XX, 3BAL-4041-XX, 3BAL-3501-XX, 3BAL-5001-XX, 3BAL-7501-XX

Telecom Cable Color Code                     Telecom Código de Color del cable
Code               Color                                        Codigo             Color
02                  Black                                            02                Negro
03                   Red                                             03                 Rojo
04                  Green                                           04                Verde
06                   Blue                                             06                 Azul
09              Gray (slate)                                      09             Gris pizarra
03TR      Red with black tracer                          03TR      Rojo con linea negra
06TR      Blue with black tracer                          06TR      Azul con linea negra
09TR      Gray with black tracer                         09TR      Gris con linea negra

Power Cable RHH ST1 KS24194 L3 en: Tijuana, Rosarito, Mexicali, Ensenada, Tecate, San Luis Rio Colorado, Son, La Paz, BCS, Los Cabos BCS, Mexico

Etiquetado con: , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,
Publicado en: Cable y Alambre, Wire and Cable

TORRE ARRIOSTRADA PARA TELECOMUNICACIONES

TORRE ARRIOSTRADA PARA TELECOMUNICACIONES

TORRE ARRIOSTRADA PARA TELECOMUNICACIONES

STZ-30, STZ30G, STZ-35, STZ-35G, STZ-45, STZ-45G, SCZ, SBA-30,

TORRE ARRIOSTRADA PARA TELECOMUNICACIONES

Somos distribuidores de Torre Arriostrada para Telecomunicaciones, contamos con departamento de soporte técnico donde podemos apoyarlo en la torre apropiada para su solución requerida, combinando Telecomunicaciones y Pararrayos en una misma torre, protegiendo sus equipos inalambricos.

Contactanos en www.innovative.com.mx  Tel: (664) 621 30 09 / 621 37 36 ventas@innovative.com.mx  INNOVATIVE TRADE CENTER, Tijuana, Baja California, soporte@innovative.com.mx

¿Qué son Torre Arriostrada para Telecomunicaciones

Se trata de torres de telecomunicaciones soportadas por tensores, conocidas como torres arriostradas o torres con tirantes, los tensores son generalmente de acero de alta resistencia. Una torre de comunicación con tirantes es capaz de proporcionar gran altura con un costo mucho más bajo de material. Comúnmente tiene tirantes en tres direcciones sobre radio de anclaje por lo general de 2/3 de la altura de la torre. La Torre Arriostrada para Telecomunicaciones por lo general viene con una sección de celosía triangular. Mástiles tubulares también pueden ser utilizados, sobre todo en lugares donde la formación de hielo es muy pesada y las secciones de celosía pueden llenarse de hielo con facilidad.

Ventajas y restricciones de Torre Arriostrada para Telecomunicacione

En comparación con la torre autoportante, un torre arriostrada es mucho más ligera en peso pero requiere mayor espacio libre para el anclaje de los cables. Cuando se cuenta con un espacio amplio las torres arriostradas son una buena elección.

Debido a su estructura, la Torres Arriostrada para Telecomunicaciones también tienen algunas restricciones, Por ejemplo, hay algunas limitaciones en el montaje de antenas de plato para mástiles de telecomunicación, también es necesario un gran bloque de anclaje para sostener los alambres.

TORRE ARRIOSTRADA 1

Torre de comunicación de microondas

La torre de comunicación de microondas es una estructura de altura diseñada para apoyar las antenas parabólicas que se utilizan al enviar y recibir en sistemas de microondas de electrones. La torre de comunicación de microondas tiene la misma estructura de la torre de comunicaciones común, la diferencia entre los dos tipos de antenas de radio se encuentra en el tipo de antena que apoyan. Solemos llamar a la torre especialmente construida para soportar una antena parabólica, cajas de antena o antenas de parrilla torre de comunicación de microondas.

Torre de radio, Torre de televisión

La torre de radio y televisión se refiere a una estructura alta que proporciona espacio de montaje para, antenas de televisión, radio AM y FM. se fabrican torres de radio y torres de televisión, tanto arriostradas como autosoportadas.

La estructura de nuestra torre de radio y torre de televisión no sólo cumple con el requisito para la emisión y para el soporte de las antenas de televisión, también es de un aspecto estético y acorde con el entorno

Torre Arriostrada para Telecomunicaciones en San Luis Rio Colorado, Mexicali, Tecate, Tijuana, Rosarito, Ensenada, La Paz, Los Cabos

STZ-30, STZ30G, STZ-35, STZ-35G, STZ-45, STZ-45G, SCZ, SBA-30,

Etiquetado con: , , , , , , , , , , , , , , , , , , ,
Publicado en: Soluciones

RHH ST1 KS24194 L2

RHH ST1 KS24194 L2

Power Cable RHH ST1 KS24194 L2

RHH ST1 KS24194 L2

3BALU-0801-XX, 3BALU-0601-XX, 3BALU-0401-XX, 3BALU-0201-XX, 3BALU-0101-XX, 3BALU-1011-XX, 3BALU-2021-XX, 3BALU-4041-XX, 3BALU-3501-XX, 3BALU-5001-XX, 3BALU-7501-XX

Somos Especialistas en Cables. Distribuimos en toda la Republica Mexicana: Innovative Trade Center, Tel: (664) 621 33 36 / 621 30 09 ventas@innovative.com.mx, soporte@innovative.com.mx, Tijuana, B. C. www.innovative.com.mx

Power Cable RHH ST1 KS24194 L2

no trenzada
600 V
105 ° C en seco, en húmedo 60 ° C
PRESUPUESTO
1. CONDUCTOR: Clase I modificado agrupado (8 y 6 AWG) o una cuerda-agrupado (4 AWG y mayores) trenzado de cobre estañado se ajuste a los requisitos de la norma ASTM B-33 y UL, tamaños
8 AWG a través de 750 kcmil
2. AISLAMIENTO: 105 ° C puntuación humo limitado, libre de halógenos TelcoHyde 5221 conforme a las normas UL 44, 758 Temas 509 y CSA C22.2 No.210.2 M90, además,
TelcoHyde 5221 cumple con los requisitos de Telcordia Especificación GR-347-CORE, el aislamiento tiene un Índice límite de oxígeno de 35%
3. CARACTERÍSTICAS: Una cinta de aluminio / poliéster opaca se aplicarán sobre el conductor para facilitar la extracción, el humo limitado, no halogenado con aislamiento
4. NORMAS: UL Listed RHH / LS y VW-1 CSA para la prueba de la llama / humo / ST1 FT4, tamaños 1/0 AWG y más grandes son UL «para CT Uso» (bandeja de cables) nominal, libre de plomo y libre de silicona ,
Cumple la directiva europea RoHS, cumple con Telcordia GR-347-CORE
5. Temperatura: 105 ° C en seco, en húmedo 60 ° C
6. VOLTAJE: 600 V, FT4, ST1
APLICACIONES
cable de transmisión de telecomunicaciones. Los cables están diseñados para su uso en circuitos de 600 V CA o CC en las telecomunicaciones oficinas centrales, sitios inalámbricos, estaciones repetidoras, datos
y otros centros de UPS y sistemas de administración de energía. El cable puede ser instalado en bandejas, bastidores, o conducto en aplicaciones horizontales y verticales

Todos los números de referencia requieren descripción del código de color.
Vea la tabla de código de color

Power Cable RHH ST1 KS24194 L2

Non braided
600 V
105°C dry, 60°C wet
SPECIFICATIONS
1. CONDUCTOR: Class I modified bunched (8 and 6 AWG) or rope-bunched (4 AWG and larger) stranded tin-coated copper conforming to ASTM B-33 and UL requirements, sizes
8 AWG thru 750 kcmil
2. INSULATION: 105°C rated limited smoke, zero halogen TelcoHyde 5221 conforming to UL Standards 44, 758 Subjects 509 and CSA C22.2 No.210.2 M90, in addition,
TelcoHyde 5221 complies with the requirements of Telcordia Specification GR-347-CORE, the insulation has a Limiting Oxygen Index of 35%
3. FEATURES: An opaque aluminum/polyester tape shall be applied over the conductor to facilitate stripping, limited smoke, non-halogenated insulated
4. STANDARDS: UL Listed RHH/LS and VW-1 CSA for the FT4/ST1 flame/smoke test, sizes 1/0 AWG and larger are UL «for CT Use» (Cable Tray) rated, lead-free and silicone free,
meets European RoHS directive, complies with Telcordia GR-347-CORE
5. TEMPERATURE: 105°C dry, 60°C wet
6. VOLTAGE: 600 V, FT4, ST1
APPLICATIONS
Telecommunications power cable. The cables are designed for use in 600 V AC or DC circuits in telecommunications central offices, wireless sites, repeater stations, data
centers and other UPS and power management systems. The cable can be installed in trays, racks, or conduit in horizontal and vertical applications

All part numbers require color code description.
See Color Code chart

3BALU-0801-XX, 3BALU-0601-XX, 3BALU-0401-XX, 3BALU-0201-XX, 3BALU-0101-XX, 3BALU-1011-XX, 3BALU-2021-XX, 3BALU-4041-XX, 3BALU-3501-XX, 3BALU-5001-XX, 3BALU-7501-XX

Telecom Cable Color Code                     Telecom Código de Color del cable
Code               Color                                        Codigo             Color
02                  Black                                            02                Negro
03                   Red                                             03                 Rojo
04                  Green                                           04                Verde
06                   Blue                                             06                 Azul
09              Gray (slate)                                      09             Gris pizarra
03TR      Red with black tracer                          03TR      Rojo con linea negra
06TR      Blue with black tracer                          06TR      Azul con linea negra
09TR      Gray with black tracer                         09TR      Gris con linea negra

Power Cable RHH ST1 KS24194 L2 en: Tijuana, Rosarito, Mexicali, Ensenada, Tecate, San Luis Rio Colorado, Son, La Paz, BCS, Los Cabos BCS, Mexico

Etiquetado con: , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,
Publicado en: Cable y Alambre, Wire and Cable

5 15 kV Jumper Cable Nonshielded

5 15 kV Jumper Cable Nonshielded

Power Cable 5 15 kV Jumper Cable Nonshielded

5 15 kV Jumper Cable Nonshielded

5R-0201, 5R-0101, 5R-1011, 5R-2021, 5R-4041, 5R-3501, 5R-5001

Somos Especialistas en Cables. Distribuimos en toda la Republica Mexicana: Innovative Trade Center, Tel: (664) 621 33 36 / 621 30 09 ventas@innovative.com.mx, soporte@innovative.com.mx, Tijuana, B. C. www.innovative.com.mx

Power Cable 5 15 kV Jumper Cable Nonshielded

aislamiento EPR / chaqueta
ESPECIFICACIONES
1. CONDUCTOR:, cobre cuerda trenzado, flexible y abierto con una cinta semiconductora aplicada sobre
el conductor
2. AISLAMIENTO: Etileno Propileno Red de goma (EPR) por ICEA S-96-659 (NEMA WC71)
3. AMPACIDAD: Basado en un solo conductor aislado aislado en el aire con una temperatura del conductor de 90 ° C y una temperatura ambiente de 40 ° C por 2008 Cuadro NEC 310.69
4. Temperatura: 90 ° C
5. TENSIÓN: 5/15 kV
APLICACIONES
cables de puente temporales están destinados a ser utilizados como carburantes flexibles conduce a porciones de derivación de líneas eléctricas aéreas. También se utilizan en equipos donde un no apantallado flexibles
se requiere un cable.

Diámetros y pesos pueden variar entre los fabricantes.
Nota: Cables de puente no deben ser usados en lugar de los cables de media tensión apantallados.
Deben utilizarse sólo en áreas donde el contacto con la gente y conexiones a tierra es limitada.
El acceso a estos cables debe limitarse al personal autorizado.

Power Cable 5 15 kV Jumper Cable Nonshielded

EPR insulation/jacket
SPECIFICATIONS
1. CONDUCTOR: Extra flexible, rope-stranded copper with a semi-conducting tape applied over
the conductor
2. INSULATION: Red Ethylene Propylene Rubber (EPR) per ICEA S-96-659 (NEMA WC71)
3. AMPACITY: Based on insulated single conductor isolated in air with a conductor temperature of 90°C and an ambient temperature of 40°C per 2008 NEC Table 310.69
4. TEMPERATURE: 90°C
5. VOLTAGE: 5/15 kV
APPLICATIONS
Temporary jumper cables are intended for use as flexible power leads to by-pass portions of aerial power lines. They are also used in equipment where a nonshielded flexible
cable is required.

Diameters and weights may vary among manufacturers.
Note: Jumper cables should not be used in place of shielded medium-voltage cables.
They should be used only in areas where contact with people and electrical grounds is limited.
Access to these cables must be limited to authorized personnel.

5R-0201, 5R-0101, 5R-1011, 5R-2021, 5R-4041, 5R-3501, 5R-5001

Power Cable 5 15 kV Jumper Cable Nonshielded en: Tijuana, Rosarito, Mexicali, Ensenada, Tecate, San Luis Rio Colorado, Son, La Paz, BCS, Los Cabos BCS, Mexico

Etiquetado con: , , , , , , , , , , , , , , , , , , , , , ,
Publicado en: Cable y Alambre, Wire and Cable

Belden VFD

Belden VFD

Power Cable Belden VFD

Belden VFD

3ACD-0103-1KV-B, 3ACD-1013-1KV-B, 3ACD-2023-1KV-B, 3ACD-3033-1KV-B, 3ACD-4043-1KV-B, 2ACD-1603FB-1KV-B, 2ACD-1403FB-1KV-B, 2ACD-1203FB-1KV-B, 2ACD-1003FB-1KV-B, 3ACD-0803FB-1KV-B, 3ACD-0603FB-1KV-B, 3ACD-0403FB-1KV-B, 3ACD-0203FB-1KV-B, 2ACD-1603+16-1PR-B, 2ACD-1403+16-1PR-B, 2ACD-1203+16-1PR-B, 2ACD-1003+16-1PR-B

Somos Especialistas en Cables. Distribuimos en toda la Republica Mexicana: Innovative Trade Center, Tel: (664) 621 33 36 / 621 30 09 ventas@innovative.com.mx, soporte@innovative.com.mx, Tijuana, B. C. www.innovative.com.mx

Power Cable Belden VFD

aislamiento XLPE
El forro de PVC
Lista UL Tipo TC
90 ° C, 1.000 V
PRESUPUESTO
1. CONDUCTOR: Trenzado, cobre estañado según ASTM B-3, B-33
2. Aislamiento: Polietileno reticulado (XLPE) por ICEA S-95-685 (NEMA WC70) cumple con los requisitos de UL
3. CÓDIGO DE COLORES: conductores del circuito se codifican según el método de ICEA (4 números impresos)
4. MONTAJE: Cinta de cobre blindado: trenzado de 3 conductores conductores TC más tres motivos de cobre desnudo. Aluminio / trenzado apantallado: 3 conductores varados TC más uno de PVC de tamaño completo
con aislamiento a tierra verde. drenaje TC frigorífico
5. Normas: Cumple con los requisitos de UL para cables TC tipo que tiene XHHW-2 conductores. Los cables se enumeran para el entierro directo y cumplen con la norma IEEE 1202, IEEE 383 y UL 1685,
70.000 BTU / hr ensayos a la llama, así como la ICEA T-29-520, 210,000 BTU ensayo a la llama / hr. cables de aluminio / trenzado también están clasificados para UL 1000 V aplicaciones cable del motor flexible.
6. AMPACIDAD: Basado en no más de tres conductores en la pista de rodadura cable o tierra según la Tabla NEC 310.16 con una temperatura del conductor de 90 ° C y una temperatura ambiente de
30 ° C. Todos los valores de 4 conductores han sido reducida por 2008 Cuadro NEC 310.15 (B) (2) (a)
7. Temperatura: 90 ° C
8. Voltaje: 600 V / 1 kV
APLICACIONES
unidades de frecuencia variable (VFD), también conocido como de velocidad variable o de velocidad ajustable unidades se utilizan para motores de corriente alterna de energía en una variedad de control de movimiento industrial, comercial
aplicaciones de flujo / bombeo, y extrusión. Beneficios del uso de un variador de frecuencia respecto a las unidades tradicionales de CC incluyen control del motor más preciso y una mayor eficiencia de energía. Mientras que hay
muchos beneficios para el uso de variadores de frecuencia, su uso requiere consideraciones especiales para los otros componentes del sistema de accionamiento; sobre todo el cableado de salida del variador. Estos sistemas de accionamiento
requiere cables que están diseñados específicamente para aplicaciones de VFD con el fin de mejorar la fiabilidad del sistema de accionamiento, mientras que la negación de los efectos de RFI / EMI.

Power Cable Belden VFD

XLPE insulation
PVC jacket
UL Listed Type TC
90°C , 1,000 V
SPECIFICATIONS OF
1. CONDUCTOR: Stranded, tinned copper per ASTM B-3, B-33
2. INSULATION: Cross-Linked Polyethylene (XLPE) per ICEA S-95-685 (NEMA WC70) meets UL requirements
3. COLOR CODE: Circuit conductors are coded per ICEA Method 4 (printed numbers)
4. ASSEMBLY: Copper tape shielded: 3-conductor stranded TC conductors plus three bare copper grounds. Foil/braid shielded: 3 stranded TC conductors plus one full-sized PVC
insulated green ground. Full-sized TC drain
5. STANDARDS: Meets the UL requirements for Type TC cables having XHHW-2 conductors. Cables are listed for direct burial and meet the IEEE 1202, IEEE 383, and UL 1685,
70,000 Btu/hr flame tests as well as the ICEA T-29-520, 210,000 Btu/hr flame test. Foil/braid cables are also UL rated for 1,000 V Flexible Motor Supply Cable applications.
6. AMPACITY: Based on not more than three conductors in raceway or cable or earth per NEC Table 310.16 with a conductor temperature of 90°C and an ambient temperature of
30°C. All 4-conductor values have been derated per 2008 NEC Table 310.15(B)(2)(a)
7. TEMPERATURE: 90°C
8. VOLTAGE: 600 V / 1 kV
APPLICATIONS
Variable-frequency drives (VFDs), also known as variable-speed or adjustable-speed drives are used to power AC motors in a variety of industrial motion control, commercial
flow/pumping, and extrusion applications. Benefits of using a VFD over traditional DC drives include more precise motor control and improved power efficiency. While there
are many benefits to using VFDs, their use requires special considerations for other drive system components; especially the drive’s output cabling. These drive systems
require cables that are specifically designed for VFD applications in order to improve drive system reliability while negating the impact of RFI/EMI

1 KV COPPER TAPE SHIELD
3ACD-0103-1KV-B, 3ACD-1013-1KV-B, 3ACD-2023-1KV-B, 3ACD-3033-1KV-B, 3ACD-4043-1KV-B

1 KV OVERALL FOIL PLUS 85% TC BRAID SHIELD
2ACD-1603FB-1KV-B, 2ACD-1403FB-1KV-B, 2ACD-1203FB-1KV-B, 2ACD-1003FB-1KV-B, 3ACD-0803FB-1KV-B, 3ACD-0603FB-1KV-B, 3ACD-0403FB-1KV-B, 3ACD-0203FB-1KV-B

1 KV VFD WITH BRAKE PAIR
2ACD-1603+16-1PR-B, 2ACD-1403+16-1PR-B, 2ACD-1203+16-1PR-B, 2ACD-1003+16-1PR-B

Power Cable Belden VFD en: Tijuana, Rosarito, Mexicali, Ensenada, Tecate, San Luis Rio Colorado, Son, La Paz, BCS, Los Cabos BCS, Mexico

Etiquetado con: , , , , , , , , , , , , , , , , , , , , , , , ,
Publicado en: Cable y Alambre, Wire and Cable

VFD

VFD

Power Cable VFD

VFD

2ACD-1403, 2ACD-1203, 2ACD-1003, 3ACD-0803, 3ACD-0603, 3ACD-0403, 3ACD-0203, 3ACD-1013, 2ACD-1403-2KV, 2ACD-1203-2KV, 2ACD-1003-2KV, 3ACD-0803-2KV, 3ACD-0603-2KV, 3ACD-0403-2KV, 3ACD-0203-2KV, 3ACD-1013-2KV, 3ACD-2023-2KV, 3ACD-4043-2KV, 3ACD-3503-2KV, 3ACD-5003-2KV

Somos Especialistas en Cables. Distribuimos en toda la Republica Mexicana: Innovative Trade Center, Tel: (664) 621 33 36 / 621 30 09 ventas@innovative.com.mx, soporte@innovative.com.mx, Tijuana, B. C. www.innovative.com.mx

Power Cable VFD

aislamiento XLP
El forro de PVC
escriba TC
90 ° C
UL Listed
PRESUPUESTO
1. CONDUCTOR: Clase B trenzado, de cobre estañado según ASTM B-3, B-33
2. Aislamiento: Polietileno reticulado (XLP) por ICEA S-95-685 (NEMA WC70) cumple con los requisitos de UL
3. CÓDIGO DE COLORES: Los conductores están codificados según el método de ICEA (4 números impresos)
4. Montaje: Tres conductores aislados están cableados con tres motivos sin aislamiento y blindaje total cinta de cobre
5. CHAQUETA EN GENERAL: Negro luz solar resistente al cloruro de polivinilo (PVC) por UL 1277
6. NORMAS: Cumple con los requisitos de UL para cables TC tipo que tiene XHHW-2 conductores. Los cables se enumeran para el entierro directo y cumplen con la norma IEEE 1202, IEEE 383 y UL 1685,
70.000 BTU / hr pruebas de llama, así como la ICEA T-29-520, 210.000 BTU / hr prueba de llama
7. AMPACIDAD: Basado en no más de tres conductores en la pista de rodadura cable o tierra por 2008 Cuadro NEC 310.16 con una temperatura del conductor de 90 ° C y una temperatura ambiente
temperatura de 30 ° C. Todos los valores de 4 conductores han sido reducida por 2008 Cuadro NEC 310.15 (B) (2) (a)
8. Temperatura: 90 ° C
9. VOLTAJE: 600 V o 2 kV
APLICACIONES
unidades de frecuencia variable (VFD), también conocido como de velocidad variable o de velocidad ajustable unidades se utilizan para motores de corriente alterna de energía en una variedad de control de movimiento industrial, comercial
aplicaciones de flujo / bombeo, y extrusión. Beneficios del uso de un variador de frecuencia respecto a las unidades tradicionales de CC incluyen control del motor más preciso y una mayor eficiencia de energía. Mientras que hay
muchos beneficios para el uso de variadores de frecuencia, su uso requiere consideraciones especiales para los otros componentes del sistema de accionamiento; sobre todo el cableado de salida del variador. Estos sistemas de accionamiento
requiere cables que están diseñados específicamente para aplicaciones de VFD con el fin de mejorar la fiabilidad del sistema de accionamiento, mientras que la negación de los efectos de RFI / EM

Power Cable VFD

XLP insulation
PVC jacket
Type TC
90°C
UL Listed
SPECIFICATIONS
1. CONDUCTOR: Class B stranded, tinned copper per ASTM B-3, B-33
2. INSULATION: Cross-Linked Polyethylene (XLP) per ICEA S-95-685 (NEMA WC70) meets UL requirements
3. COLOR CODE: Conductors are coded per ICEA Method 4 (printed numbers)
4. ASSEMBLY: Three insulated conductors are cabled with three uninsulated grounds and an overall copper tape shield
5. OVERALL JACKET: Black sunlight-resistant Polyvinyl Chloride (PVC) per UL 1277
6. STANDARDS: Meets the UL requirements for Type TC cables having XHHW-2 conductors. Cables are listed for direct burial and meet the IEEE 1202, IEEE 383, and UL 1685,
70,000 Btu/hr flame tests as well as the ICEA T-29-520, 210,000 Btu/hr flame test
7. AMPACITY: Based on not more than three conductors in raceway or cable or earth per 2008 NEC Table 310.16 with a conductor temperature of 90°C and an ambient
temperature of 30°C. All 4-conductor values have been derated per 2008 NEC Table 310.15(B)(2)(a)
8. TEMPERATURE: 90°C
9. VOLTAGE: 600 V or 2 kV
APPLICATIONS
Variable-frequency drives (VFDs), also known as variable-speed or adjustable-speed drives are used to power AC motors in a variety of industrial motion control, commercial
flow/pumping, and extrusion applications. Benefits of using a VFD over traditional DC drives include more precise motor control and improved power efficiency. While there
are many benefits to using VFDs, their use requires special considerations for other drive system components; especially the drive’s output cabling. These drive systems
require cables that are specifically designed for VFD applications in order to improve drive system reliability while negating the impact of RFI/EM

VFD 600V
2ACD-1403, 2ACD-1203, 2ACD-1003, 3ACD-0803, 3ACD-0603, 3ACD-0403, 3ACD-0203, 3ACD-1013

VFD 2 KV
2ACD-1403-2KV, 2ACD-1203-2KV, 2ACD-1003-2KV, 3ACD-0803-2KV, 3ACD-0603-2KV, 3ACD-0403-2KV, 3ACD-0203-2KV, 3ACD-1013-2KV, 3ACD-2023-2KV, 3ACD-4043-2KV, 3ACD-3503-2KV, 3ACD-5003-2KV

Power Cable VFD en: Tijuana, Rosarito, Mexicali, Ensenada, Tecate, San Luis Rio Colorado, Son, La Paz, BCS, Los Cabos BCS, Mexico

Etiquetado con: , , , , , , , , , , , , , , , , , , , , , , , , , , , ,
Publicado en: Cable y Alambre, Wire and Cable

Single Conductor Type GTO

Single Conductor Type GTO

Power Cable Single Conductor Type GTO

Single Conductor Type GTO

3GTO-15

Somos Especialistas en Cables. Distribuimos en toda la Republica Mexicana: Innovative Trade Center, Tel: (664) 621 33 36 / 621 30 09 ventas@innovative.com.mx, soporte@innovative.com.mx, Tijuana, B. C. www.innovative.com.mx

Power Cable Single Conductor Type GTO

aislamiento PE
El forro de PVC
no apantallado
ESPECIFICACIONES
1. Conductor: Cobre estañado flexible
2. Aislamiento: Polietileno (PE), de color negro, cumple con la norma UL 814 tubos de gas-Sign y cables de encendido
APLICACIONES
Se usa entre terminales de alta tensión en los transformadores de signos y síntomas. También se utiliza para el cable de encendido del quemador de aceite. Este cable puede utilizarse en interiores o al aire libre. Aprobada para ser usada
Artículo por NEC 600,32 – neón secundaria Circuito-cableado, más de 1.000 voltios

Diámetros y pesos pueden variar entre los fabricantes.

Power Cable Single Conductor Type GTO

PE insulation
PVC jacket
Nonshielded
SPECIFICATIONS
1. CONDUCTOR: Flexible tinned copper
2. INSULATION: Polyethylene (PE), black in color, meets UL Standard 814 Gas-Tube-Sign and Ignition Cable
APPLICATIONS
Used between high-voltage terminals on sign transformers and signs. Also used for oil burner ignition cable. This cable may be used indoors or outdoors. UL Listed for use
per NEC Article 600.32 – Neon Secondary-Circuit Wiring, over 1,000 volts

Diameters and weights may vary among manufacturers.

3GTO-15

Power Cable Single Conductor Type GTO en: Tijuana, Rosarito, Mexicali, Ensenada, Tecate, San Luis Rio Colorado, Son, La Paz, BCS, Los Cabos BCS, Mexico

Etiquetado con: , , , , , , , , , , , , , , , , , , , , , , ,
Publicado en: Cable y Alambre, Wire and Cable

Single Conductor Type L 824 B L 824 C

Single Conductor Type L 824 B L 824 C

Power Cable Single Conductor Type L 824 B L 824 C

Single Conductor Type L 824 B L 824 C

3Z-0805B, 3Z-0805C, 3Z-0605C

Somos Especialistas en Cables. Distribuimos en toda la Republica Mexicana: Innovative Trade Center, Tel: (664) 621 33 36 / 621 30 09 ventas@innovative.com.mx, soporte@innovative.com.mx, Tijuana, B. C. www.innovative.com.mx

Power Cable Single Conductor Type L 824 B L 824 C

aprobado por la FAA
no apantallado
PRESUPUESTO
1. Los cables completadas se ajustan a la Agencia Federal de Aviación (FAA) Especificación L-824, última edición
2. Tipo B 5.000 V: Recocido, conductor de cobre suave dibujado, Clase B Trenzado; separador adecuado
cinta de 90 ° C de aislamiento EPR; El forro de PVC (otros chaquetas opcional) en general; L-824-B imprimió más el tamaño del conductor, la tensión y el nombre del fabricante de superficie
3. Tipo C 5,000 V: Recocido, conductor de cobre suave dibujado, Clase B Trenzado; cinta aislante 90 ° C XLP separador adecuado; superficie impresa L-824-C más el tamaño del conductor, el voltaje
y el nombre del fabricante
APLICACIONES
Para su uso en instalaciones subterráneas para la iluminación y de control del aeropuerto.

Diámetros y pesos pueden variar entre los fabricantes

Power Cable Single Conductor Type L 824 B L 824 C

FAA approved
Nonshielded
SPECIFICATIONS
1. Completed cables conform to Federal Aviation Agency (FAA) Specification L-824, latest edition
2. Type B 5,000 V: Annealed, soft-drawn copper conductor, Class B stranded; suitable separator
tape 90°C EPR insulation; PVC jacket (other jackets optional) overall; surface printed L-824-B plus conductor size, voltage and manufacturer’s name
3. Type C 5,000 V: Annealed, soft-drawn copper conductor, Class B stranded; suitable separator tape 90°C XLP insulation; surface printed L-824-C plus conductor size, voltage
and manufacturer’s name
APPLICATIONS
For use in underground installations for airport lighting and control.

Diameters and weights may vary among manufacturers

3Z-0805B, 3Z-0805C, 3Z-0605C

Power Cable Single Conductor Type L 824 B L 824 C en: Tijuana, Rosarito, Mexicali, Ensenada, Tecate, San Luis Rio Colorado, Son, La Paz, BCS, Los Cabos BCS, Mexico

Etiquetado con: , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,
Publicado en: Cable y Alambre, Wire and Cable

EPR PVC Copper Tape Shield 35kV

EPR PVC Copper Tape Shield 35kV

Power Cable EPR PVC Copper Tape Shield 35kV

EPR PVC Copper Tape Shield 35kV

3DX-1011, 3DX-2021, 3DX-3031, 3DX-4041, 3DX-2501, 3DX-3501, 3DX-5001, 3DX-7501, 3DX-10001

Somos Especialistas en Cables. Distribuimos en toda la Republica Mexicana: Innovative Trade Center, Tel: (664) 621 33 36 / 621 30 09 ventas@innovative.com.mx, soporte@innovative.com.mx, Tijuana, B. C. www.innovative.com.mx

Power Cable EPR PVC Copper Tape Shield 35kV

aislamiento de EPR
El forro de PVC
blindado
nivel de aislamiento 100%
ESPECIFICACIONES DE
1. CONDUCTOR: Clase B trenzado, cobre recocido según la norma ASTM B-3 y B-8, escudo hebra es un semiconductor termoestable extruida
2. AISLAMIENTO: Caucho de etileno propileno (EPR) por ICEA S-93-639 (NEMA WC74)
3. AISLAMIENTO SHIELD: blindaje de aislamiento extruido termoestable semiconductor. Escudo metálico se encuentra a 5 milésimas de pulgada de cinta de blindaje de cobre sin recubrimiento aplicado helicoidalmente
4. CHAQUETA EN GENERAL: La luz solar resistente, negro cloruro de polivinilo (PVC)
5. NORMAS: engloban en el tipo MV-105 por UL 1072 y cumple con los requisitos de ICEA S-93-639. Tamaños 1/0 y pase más grande UL 1685 de 70.000 Btu / hr prueba de llama
6. AMPACIDAD: Sobre la base de tres cables conductores individuales aislados en el conducto de aire de acuerdo con la Tabla NEC 310.73 con una temperatura del conductor de 90 ° C y una temperatura ambiente de 40 ° C
7. Temperatura: 105 ° C
8. Voltaje: 35 kV
APLICACIONES
Para su uso en circuitos de potencia de hasta 35 kV cuando se instala en el aire abierto, conducto, el conducto o el enterramiento directo para lugares húmedos o secos. Se utiliza para aplicaciones de potencia en plantas químicas,
refinerías, fábricas de acero, plantas industriales, subestaciones y centrales eléctricas.

0,420 pulg. Espesor de aislamiento (nivel de aislamiento 133%) disponibles bajo petición.
Diámetros y pesos pueden variar entre los fabricantes.

Power Cable EPR PVC Copper Tape Shield 35kV

EPR insulation
PVC jacket
Shielded
100% insulation level
SPECIFICATIONS OF
1. CONDUCTOR: Class B stranded, annealed copper per ASTM B-3 and B-8, strand shield is an extruded semiconducting thermoset
2. INSULATION: Ethylene Propylene Rubber (EPR) per ICEA S-93-639 (NEMA WC74)
3. INSULATION SHIELD: Extruded semiconducting thermoset insulation shield. Metallic shield is a helically applied 5 mil uncoated copper shielding tape
4. OVERALL JACKET: Sunlight-resistant, black Polyvinyl Chloride (PVC)
5. STANDARDS: Listed as Type MV-105 per UL 1072 and meets the requirements of ICEA S-93-639. Sizes 1/0 and larger pass UL 1685 70,000 Btu/hr flame test
6. AMPACITY: Based on three single conductor cables in isolated conduit in air per NEC Table 310.73 with a conductor temperature of 90°C and an ambient temperature of 40°C
7. TEMPERATURE: 105°C
8. VOLTAGE: 35 kV
APPLICATIONS
For use in power circuits up to 35 kV when installed in open air, conduit, duct or direct burial for wet or dry locations. Used for power applications in chemical plants,
refineries, steel mills, industrial plants, utility substations and generating stations.

0.420 in. insulation thickness (133% insulation level) available upon request.
Diameters and weights may vary among manufacturers.

3DX-1011, 3DX-2021, 3DX-3031, 3DX-4041, 3DX-2501, 3DX-3501, 3DX-5001, 3DX-7501, 3DX-10001

Power Cable EPR PVC Copper Tape Shield 35kV en: Tijuana, Rosarito, Mexicali, Ensenada, Tecate, San Luis Rio Colorado, Son, La Paz, BCS, Los Cabos BCS, Mexico

Etiquetado con: , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,
Publicado en: Cable y Alambre, Wire and Cable

Lead free EPR PVC Copper Tape Shield 35kV

Lead free EPR PVC Copper Tape Shield 35kV

Power Cable Lead free EPR PVC Copper Tape Shield 35kV

Lead free EPR PVC Copper Tape Shield 35kV

3DX-1011-SW, 3DX-2021-SW, 3DX-3031-SW, 3DX-4041-SW, 3DX-2501-SW, 3DX-3501-SW, 3DX-5001-SW, 3DX-7501-SW, 3DX-10001-SW

Somos Especialistas en Cables. Distribuimos en toda la Republica Mexicana: Innovative Trade Center, Tel: (664) 621 33 36 / 621 30 09 ventas@innovative.com.mx, soporte@innovative.com.mx, Tijuana, B. C. www.innovative.com.mx

Power Cable Lead free EPR PVC Copper Tape Shield 35kV

aislamiento de EPR
El forro de PVC
blindado
nivel de aislamiento 100%
Sin plomo
No se requiere lubricación
ESPECIFICACIONES DE
1. CONDUCTOR: Clase B trenzado, cobre recocido según la norma ASTM B-3 y B-8. escudo Strand es un semiconductor termoestable extruida
2. AISLAMIENTO: Caucho de etileno propileno (EPR) por ICEA S-93-639 (NEMA WC74)
3. AISLAMIENTO SHIELD: semiconductora extruida, pantalla de aislamiento termoestable. Escudo metálico se encuentra a 5 milésimas de pulgada de cinta de blindaje de cobre sin recubrimiento aplicado helicoidalmente
4. CHAQUETA EN GENERAL: La luz solar resistente, negro cloruro de polivinilo (PVC). Lubricante incorporado en la chaqueta para facilitar la instalación
5. NORMAS: engloban en el tipo MV-105 por UL 1072 y cumple con los requisitos de ICEA S-93-639 (NEMA WC74). Tamaños 1/0 y pase más grande UL 1685 de 70.000 Btu / hr prueba de llama
6. AMPACIDAD: Sobre la base de tres cables conductores individuales aislados en el conducto de aire de acuerdo con la Tabla NEC 310.73 con una temperatura del conductor de 90 ° C y una temperatura ambiente de 40 ° C
7. Temperatura: 105 ° C
8. Voltaje: 35 kV
APLICACIONES
Para su uso en circuitos de potencia de hasta 35 kV cuando se instala en el aire abierto, conducto, el conducto o el enterramiento directo para lugares húmedos o secos. Se utiliza para aplicaciones de potencia en plantas químicas,
refinerías, fábricas de acero, plantas industriales, subestaciones y centrales eléctricas.

0,420 pulg. Espesor de aislamiento (nivel de aislamiento 133%) disponibles bajo petición.
Diámetros y pesos pueden variar entre los fabricantes.

Power Cable Lead free EPR PVC Copper Tape Shield 35kV

EPR insulation
PVC jacket
Shielded
100% insulation level
Lead-free
No lube required
SPECIFICATIONS OF
1. CONDUCTOR: Class B stranded, annealed copper per ASTM B-3 and B-8. Strand shield is an extruded semiconducting thermoset
2. INSULATION: Ethylene Propylene Rubber (EPR) per ICEA S-93-639 (NEMA WC74)
3. INSULATION SHIELD: Extruded semiconducting, thermoset insulation shield. Metallic shield is a helically applied 5 mil uncoated copper shielding tape
4. OVERALL JACKET: Sunlight-resistant, black Polyvinyl Chloride (PVC). Lubricant built into jacket to facilitate installation
5. STANDARDS: Listed as Type MV-105 per UL 1072 and meets the requirements of ICEA S-93-639 (NEMA WC74). Sizes 1/0 and larger pass UL 1685 70,000 Btu/hr flame test
6. AMPACITY: Based on three single conductor cables in isolated conduit in air per NEC Table 310.73 with a conductor temperature of 90°C and an ambient temperature of 40°C
7. TEMPERATURE: 105°C
8. VOLTAGE: 35 kV
APPLICATIONS
For use in power circuits up to 35 kV when installed in open air, conduit, duct or direct burial for wet or dry locations. Used for power applications in chemical plants,
refineries, steel mills, industrial plants, utility substations and generating stations.

0.420 in. insulation thickness (133% insulation level) available upon request.
Diameters and weights may vary among manufacturers.

3DX-1011-SW, 3DX-2021-SW, 3DX-3031-SW, 3DX-4041-SW, 3DX-2501-SW, 3DX-3501-SW, 3DX-5001-SW, 3DX-7501-SW, 3DX-10001-SW

Power Cable Lead free EPR PVC Copper Tape Shield 35kV en: Tijuana, Rosarito, Mexicali, Ensenada, Tecate, San Luis Rio Colorado, Son, La Paz, BCS, Los Cabos BCS, Mexico

 

Etiquetado con: , , , , , , , , , , , , , , , , , , , , , , , , , , ,
Publicado en: Cable y Alambre, Wire and Cable
Comentarios recientes
Archivos
Subscribase a este sitio