RHH RHW 2 USE 2 XLP

RHH RHW 2 USE 2 XLP

Building Cable RHH RHW 2 USE 2 XLP

RHH RHW 2 USE 2 XLP

3B-1401, 3B-1201, 3B-1001, 3B-0801, 3B-0601, 3B-0401, 3B-0201,3B-0101, 3B-1011, 3B-2021, 3B-3031, 3B-4041, 3B-2501, 3B-3501, 3B-5001, 3B-7501, 3B-10001

Somos Especialistas en Cables. Distribuimos en toda la Republica Mexicana: Innovative Trade Center, Tel: (664) 621 33 36 / 621 30 09 ventas@innovative.com.mx, soporte@innovative.com.mx, Tijuana, B. C. www.innovative.com.mx

Building Cable RHH RHW 2 USE 2 XLP

aislamiento XLP / chaqueta
90 ° C húmedo / seco
ESPECIFICACIONES DE
1. CONDUCTOR: Bare trenzado de cobre de clase B según la norma ASTM B-8
2. Aislamiento: Polietileno reticulado (XLP)
3. NORMAS: Cable aparece como tipo USE-2 por UL 854 y RHH / RHW-2 según UL 44, cumple con la norma ICEA S-95-658 (NEMA WC70)
4. AMPACIDAD: Basado en no más de tres conductores en la pista de rodadura cable o tierra por 2008 Cuadro NEC 310.16 con una temperatura ambiente de 30 ° C
5. Temperatura: 90 ° C
6. VOLTAJE: 600 V
APLICACIONES
cableado de propósito general para los circuitos de control, centralita telefónica, alumbrado y fuerza en los edificios residenciales y comerciales, plantas industriales y de servicios públicos, para subestaciones y plantas generadoras metros

14 AWG no está clasificado como Tipo USE-2.
Diámetros y pesos pueden variar entre los fabricantes.
Todos los números de referencia requieren designación del código de color.
CT material de puntuación disponibles en tamaños de 1/0 y más grandes.

Building Cable RHH RHW 2 USE 2 XLP

XLP insulation/jacket
90°C wet/dry
SPECIFICATIONS OF
1. CONDUCTOR: Bare copper Class B stranding per ASTM B-8
2. INSULATION: Cross-Linked Polyethylene (XLP)
3. STANDARDS: Cable is listed as Type USE-2 per UL 854 and RHH/RHW-2 per UL 44, meets requirements of ICEA S-95-658 (NEMA WC70)
4. AMPACITY: Based on not more than three conductors in raceway or cable or earth per 2008 NEC Table 310.16 with an ambient temperature of 30°C
5. TEMPERATURE: 90°C
6. VOLTAGE: 600 V
APPLICATIONS
General purpose wiring for control, switchboard, lighting and power circuits in residential and commercial buildings, industrial plants and for utility substations, meters and generating plants

14 AWG is not rated as Type USE-2.
Diameters and weights may vary among manufacturers.
All part numbers require color code designation.
CT rated material available in sizes 1/0 and larger.

3B-1401, 3B-1201, 3B-1001, 3B-0801, 3B-0601, 3B-0401, 3B-0201,3B-0101, 3B-1011, 3B-2021, 3B-3031, 3B-4041, 3B-2501, 3B-3501, 3B-5001, 3B-7501, 3B-10001

Building Cable RHH RHW 2 USE 2 XLP en: Tijuana, Rosarito, Mexicali, Ensenada, Tecate, San Luis Rio Colorado, Son, La Paz, BCS, Los Cabos BCS, Mexico

Etiquetado con: , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,
Publicado en: Cable y Alambre, Wire and Cable

Deja una respuesta

Tu dirección de correo electrónico no será publicada. Los campos obligatorios están marcados con *

*

Descarga Aquí este Catálogo
Subscribase a este sitio