THHN THWN 2

THHN THWN 2

Building Wire THHN THWN 2

THHN THWN 2

6F-1401, 6F-1201, 6F-1001, 6G-1401, 6G-1201, 6G-1001, 6G-0801, 6G-0601, 6G-0401, 6G-0301, 6G-0201, 6G-0101, 6G-1011, 6G-2021, 6G-3031, 6G-4041, 6G-2501, 6G-3001, 6G-3501, 6G-4001, 6G-5001, 6G-6001, 6G-7501, 6G-10001

Somos Especialistas en Cables. Distribuimos en toda la Republica Mexicana: Innovative Trade Center, Tel: (664) 621 33 36 / 621 30 09 ventas@innovative.com.mx, soporte@innovative.com.mx, Tijuana, B. C. www.innovative.com.mx

Building Wire THHN THWN 2

Sólido o trenzado
aislamiento de PVC
chaqueta de nylon
90 ° C seca (THHN)
90 ° C húmedo (THWN-2, 8 AWG y más grande)
75 ° C húmedo (THWN)
600 V
PRESUPUESTO
1. CONDUCTOR: sólido o trenzado de cobre recocido según la norma ASTM aplicable
2. AISLAMIENTO: Policloruro de vinilo (PVC) revestida con nylon reunión los requisitos de la norma UL aplicable
3. NORMAS: UL 83 termoplástico alambre y cable, UL 1063 MTW, UL 758 AWM, Especificación Federal UNA-A-59544. Tamaños 1/0 y más grandes están marcados «para el uso de la TC». El cable es
luz solar resistente en 1/0 y más grande (negro solamente)
4. AMPACIDAD: Basado en no más de tres conductores en la pista de rodadura cable o tierra con una temperatura ambiente de 30 ° C por 2008 Cuadro NEC 310.16
5. Temperatura: 90 ° C THHN seca, THWN-2 90 ° C / seco, THWN 75 ° C mojado, MTW 90 ° C en seco, en húmedo 60 ° C / aceite mojado, AWM 105 ° C seca
6. VOLTAJE: 600 V
APLICACIONES
cableado de propósito general para la nueva construcción o modernización de los sistemas existentes. Conveniente para la iluminación y la energía en edificios residenciales, comerciales e industriales. también
recomendada para los circuitos de control de potencia, máquinas herramientas, aparatos y paneles de relés. La chaqueta general de nylon es resistente a la abrasión con una superficie resbaladiza, para una fácil tirando en
conductos. Altamente resistente a los ácidos, álcalis, productos químicos, petróleo, gasolina, grasa y las llamas.

A menos que se permita específicamente de la NEC, la protección de sobrecorriente no será superior a 15 A para 14 AWG, 20 A para 12 AWG y 30 A para 10 AWG de cobre.
Diámetros, pesos y listados adicionales pueden variar entre los fabricantes.
Todos los números de referencia requieren designación del código de color.

Building Wire THHN THWN 2

Solid or stranded
PVC insulation
Nylon jacket
90°C dry (THHN)
90°C wet (THWN-2, 8 AWG and larger)
75°C wet (THWN)
600 V
SPECIFICATIONS
1. CONDUCTOR: Solid or stranded annealed copper per applicable ASTM standard
2. INSULATION: Polyvinyl Chloride (PVC) sheathed with nylon meeting the requirements of the applicable UL standard
3. STANDARDS: UL 83 Thermoplastic Wire and Cable, UL 1063 MTW, UL 758 AWM, Federal Specification A-A-59544. Sizes 1/0 and larger are marked «for CT use». Cable is
sunlight-resistant in 1/0 and larger (black only)
4. AMPACITY: Based on not more than three conductors in raceway or cable or earth with an ambient temperature of 30°C per 2008 NEC Table 310.16
5. TEMPERATURE: THHN 90°C dry, THWN-2 90°C wet/dry, THWN 75°C wet, MTW 90°C dry, 60°C wet/oil, AWM 105°C dry
6. VOLTAGE: 600 V
APPLICATIONS
General purpose wiring for new construction or modernizing existing systems. Suitable for lighting and power in residential, commercial and industrial buildings. Also
recommended for power control circuits, machine tools, appliances and relay panels. The overall nylon jacket is abrasion resistant with slippery surface, for easy pulling in
conduits. Highly resistant to acids, alkalis, chemicals, oil, gasoline, grease and flame.

Unless otherwise specifically permitted in the NEC, the overcurrent protection shall not exceed 15 A for 14 AWG, 20 A for 12 AWG and 30 A for 10 AWG copper.
Diameters, weights and additional listings may vary among manufacturers.
All part numbers require color code designation.

6F-1401, 6F-1201, 6F-1001, 6G-1401, 6G-1201, 6G-1001, 6G-0801, 6G-0601, 6G-0401, 6G-0301, 6G-0201, 6G-0101, 6G-1011, 6G-2021, 6G-3031, 6G-4041, 6G-2501, 6G-3001, 6G-3501, 6G-4001, 6G-5001, 6G-6001, 6G-7501, 6G-10001

Building Wire THHN THWN 2 en: Tijuana, Rosarito, Mexicali, Ensenada, Tecate, San Luis Rio Colorado, Son, La Paz, BCS, Los Cabos BCS, Mexico

Etiquetado con: , , , , , , , , , , , , , , , , , , ,
Publicado en: Cable y Alambre, Wire and Cable

Deja una respuesta

Tu dirección de correo electrónico no será publicada. Los campos obligatorios están marcados con *

*

Descarga Aquí este Catálogo
Subscribase a este sitio