XHHW 2

XHHW 2

Building Cable XHHW 2

XHHW 2

6L-1401, 6L-1201, 6L-1001, 6M-1401, 6M-1201, 6M-1001, 6M-0801, 6M-0601, 6M-0401, 6M-0201, 6M-0101,6M-1011, 6M-2021, 6M-3031, 6M-4041, 6M-2501, 6M-3001, 6M-3501, 6M-4001, 6M-5001, 6M-7501, 6M-10001

Somos Especialistas en Cables. Distribuimos en toda la Republica Mexicana: Innovative Trade Center, Tel: (664) 621 33 36 / 621 30 09 ventas@innovative.com.mx, soporte@innovative.com.mx, Tijuana, B. C. www.innovative.com.mx

Building Cable XHHW 2

Sólido o trenzado
aislamiento XLP / chaqueta
90 ° C húmedo / seco
600 V
ESPECIFICACIONES DE
1. CONDUCTOR: Clase B trenzado, recocido, cobre desnudo
2. Aislamiento: Polietileno reticulado (XLP)
3. NORMAS: Se enumeran Tipo XHHW-2 por UL 44 Hilos y cables aislados-termoestable, cumple con los requisitos de construcción de ICEA S-95-658 (NEMA WC 70), se ajusta a la especificación federal A-A-595444. AMPACIDAD: Basado en no más de tres conductores en la pista de rodadura cable o tierra con una temperatura ambiente de 30 ° C por 2008 Cuadro NEC 310.165. TEMPERATURA: 90 ° C
6. VOLTAJE: 600 V
APLICACIONES
cableado de propósito general para los circuitos de control, centralita telefónica, alumbrado y fuerza en los edificios residenciales y comerciales y plantas industriales, y para subestaciones de servicios públicos, metros y plantas generadoras.

A menos que se permita específicamente de la NEC, la protección de sobrecorriente no será superior a 15 A para 14 AWG, 20 A para 12 AWG y 30 A para 10 AWG de cobre.
Diámetros y pesos pueden variar entre los fabricantes.
Todos los números de referencia requieren designación del código de color.
CT material de puntuación disponibles en tamaños de 1/0 y más grandes

Building Cable XHHW 2

Solid or stranded
XLP insulation/jacket
90°C wet/dry
600 V
SPECIFICATIONS OF
1. CONDUCTOR: Class B stranded, annealed, bare copper
2. INSULATION: Cross-Linked Polyethylene (XLP)
3. STANDARDS: Listed Type XHHW-2 per UL 44 Thermoset-Insulated Wires and Cables, meets construction requirements of ICEA S-95-658 (NEMA WC 70), conforms to Federal Specification A-A-595444. AMPACITY: Based on not more than three conductors in raceway or cable or earth with an ambient temperature of 30°C per 2008 NEC Table 310.165. TEMPERATURE: 90°C
6. VOLTAGE: 600 V
APPLICATIONS
General purpose wiring for control, switchboard, lighting and power circuits in residential and commercial buildings and industrial plants, and for utility substations, meters and generating plants.

Unless otherwise specifically permitted in the NEC, the overcurrent protection shall not exceed 15 A for 14 AWG, 20 A for 12 AWG and 30 A for 10 AWG copper.
Diameters and weights may vary among manufacturers.
All part numbers require color code designation.
CT rated material available in sizes 1/0 and larger

6L-1401, 6L-1201, 6L-1001, 6M-1401, 6M-1201, 6M-1001, 6M-0801, 6M-0601, 6M-0401, 6M-0201, 6M-0101,6M-1011, 6M-2021, 6M-3031, 6M-4041, 6M-2501, 6M-3001, 6M-3501, 6M-4001, 6M-5001, 6M-7501, 6M-10001

Building Cable XHHW 2 en: Tijuana, Rosarito, Mexicali, Ensenada, Tecate, San Luis Rio Colorado, Son, La Paz, BCS, Los Cabos BCS, Mexico

Etiquetado con: , , , , , , , , , , , , , , , , , , , ,
Publicado en: Cable y Alambre, Wire and Cable

Deja una respuesta

Tu dirección de correo electrónico no será publicada. Los campos obligatorios están marcados con *

*

Descarga Aquí este Catálogo
Subscribase a este sitio