3191 3192 3193

3191 3192 3193

Hook up and Lead wire Belden lead wire 3191 3192 3193

3191 3192 3193

3191: B34418-XX, B34416-XX, B34414-XX, B34412-XX B34418, B34416, B34414, B34412 3191: B34410-XX B34410 3192: B34408-XX, B34406-XX, B34404-XX, B34403-XX, B34402-XX B34408, B34406, B34404, B34403, B34402 3193: B34401, B34490, B34400, B34430, B34440

Somos Especialistas en Cables. Distribuimos en toda la Republica Mexicana: Innovative Trade Center, Tel: (664) 621 33 36 / 621 30 09 ventas@innovative.com.mx, soporte@innovative.com.mx, Tijuana, B. C. www.innovative.com.mx

Hook up and Lead wire Belden lead wire 3191 3192 3193

BELDEN
CSPE
conductor trenzado
CSA
ESPECIFICACIONES DE Hook up and Lead wire Belden lead wire
1. CONDUCTOR: Cobre estañado
2. AISLAMIENTO: Polietileno clorosulfonado
3. NORMAS: Clase 130 (B) los sistemas de aislamiento
4. TEMPERATURA: 105 ° C
5. TENSIÓN: 600 V (300 V para la CL 1052)
APLICACIONES DE Hook up and Lead wire Belden lead wire
Motor Clase 130 (B) conduce.

UL 3191, 600 V 105 ° C; CL 1053
Longitudes estándar de 100 pies., 500 pies. 3.000 ft., 4.000 ft. Y 5.000 pies. Algunas longitudes pueden contener carretes de varias piezas, 50 pies. Mínimo.

UL 3,191, 600 V 105 ° C (UL); 300 V 105 ° C (CSA); CL 1052
Longitudes estándar de 100 pies., 500 pies. Y 2.000 pies.

UL 3192, 600 V 105 ° C; CL 1052
Longitudes estándar de 100 pies., 250 pies., 500 pies. Y 1,000 pies

UL 3193, 600 V 105 ° C; CL 1052
Longitudes estándar de 50 pies., 100 pies. Y 250 pies. Longitudes de más de 100 pies. Puede contener carretes de varias piezas, 50 pies. Mínimas, 8 AWG y grandes tienen separador sobre el conductor.

Hook up and Lead wire Belden lead wire 3191 3192 3193

BELDEN
CSPE
Stranded conductor
CSA
SPECIFICATIONS Hook up and Lead wire Belden lead wire
1. CONDUCTOR: Tinned copper
2. INSULATION: Chlorosulfonated Polyethylene
3. STANDARDS: Class 130 (B) insulation systems
4. TEMPERATURE: 105°C
5. VOLTAGE: 600 V (300 V for CL 1052)
APPLICATIONS Hook up and Lead wire Belden lead wire
Class 130 (B) motor leads

UL 3191, 600 V 105°C; CL 1053
Standard lengths 100 ft., 500 ft. 3,000 ft., 4,000 ft. and 5,000 ft. Some lengths may contain multi-piece spools, 50 ft. minimum.

UL 3191, 600 V 105°C (UL); 300 V 105°C (CSA); CL 1052
Standard lengths 100 ft., 500 ft. and 2,000 ft.

UL 3192, 600 V 105°C; CL 1052
Standard lengths 100 ft., 250 ft., 500 ft. and 1,000 ft

UL 3193, 600 V 105°C; CL 1052
Standard lengths 50 ft., 100 ft. and 250 ft. Lengths over 100 ft. may contain multi-piece spools, 50 ft. minimum, 8 AWG and large have separator over conductor.

B34418-XX, B34416-XX, B34414-XX, B34412-XX
B34418, B34416, B34414, B34412

B34410-XX
B34410

B34408-XX, B34406-XX, B34404-XX, B34403-XX, B34402-XX
B34408, B34406, B34404, B34403, B34402

B34401, B34490, B34400, B34430, B34440

Tijuana, Rosarito, Mexicali, Ensenada, Tecate, San Luis Rio Colorado, Son, La Paz, BCS, Los Cabos BCS

Etiquetado con: , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,
Publicado en: Cable y Alambre, Wire and Cable

Deja una respuesta

Tu dirección de correo electrónico no será publicada. Los campos obligatorios están marcados con *

*

Descarga Aquí este Catálogo
Subscribase a este sitio