PVC Nylon Neoprene

PVC Nylon Neoprene

Control Cable PVC Nylon Neoprene

PVC Nylon Neoprene

1802, 1803, 1804, 1805, 1807, 1809, 1812, 1815, 1819, 1825, 1830, 1837, 1602, 1603, 1604, 1605, 1607, 1609, 1612, 1615, 1619, 1625, 1630, 1637, 1402, 1403, 1404, 1405, 1407, 1409, 1412, 1415, 1419, 1425, 1430, 1437, 1202, 1203, 1204, 1205, 1207, 1209, 1212, 1215, 1219, 1225, 1230, 1237

Somos Especialistas en Cables. Distribuimos en toda la Republica Mexicana: Innovative Trade Center, Tel: (664) 621 33 36 / 621 30 09 ventas@innovative.com.mx, soporte@innovative.com.mx, Tijuana, B. C. www.innovative.com.mx

Control Cable PVC Nylon Neoprene

filamento flexible
PVC-nylon aislamiento
chaqueta de neopreno
90 ° C, 600 V

ESPECIFACIONES
1. CONDUCTORES: Bare, cobre y recocido según la norma ASTM B-3, Clase C varados por la norma ASTM B-8
2. AISLAMIENTO: Policloruro de vinilo (PVC) con .004 en nylon extruido en general.
3. CÓDIGO DE COLORES: ICEA Método 1, Tabla E-2 (anteriormente K-2)
4. Montaje: Aislado conductores están cableados con cargas cuando sea necesario para hacer todo el año, se aplica en general una cinta con aglutinante
5. CHAQUETA EN GENERAL: policloropreno (neopreno)
6. NORMAS: Los conductores individuales cumplen con los requisitos de UL para el tipo TFFN (18-16 AWG) o de tipo THHN / THWN (14-12 AWG), cables cumplen los UL 70.000 BTU y la ICEA
T-29-520 210.000 Btu ensayos a la llama, cable acabado cumple con los requisitos de UL para cable de Tipo TC
7. AMPACIDAD: Basado en no más de tres conductores en la pista de rodadura cable o tierra con una temperatura ambiente de 30ºC según la Tabla NEC 310.16, los valores se han reducido su potencia
donde corresponda
8. Temperatura: 90 ° C
9. VOLTAJE: 600 V
APLICACIONES
Se utiliza como cable de la bandeja donde la flexibilidad adicional y requisitos de espacios confinados están involucrados en la instalación.

Control Cable PVC Nylon Neoprene

Flexible strand
PVC-nylon insulation
Neoprene jacket
90°C, 600 V
SPECIFICATIONS
1. CONDUCTORS: Bare, annealed copper per ASTM B-3, Class C stranded per ASTM B-8
2. INSULATION: Polyvinyl Chloride (PVC) with .004 in. extruded nylon overall
3. COLOR CODE: ICEA Method 1, Table E-2 (formerly K-2)
4. ASSEMBLY: Insulated conductors are cabled with fillers where necessary to make round, a binder tape is applied overall
5. OVERALL JACKET: Polychloroprene (Neoprene)
6. STANDARDS: Individual conductors meet the UL requirements for Type TFFN (18-16 AWG) or Type THHN/THWN (14-12 AWG), cables meet the UL 70,000 Btu and the ICEA
T-29-520 210,000 Btu flame tests, finished cable meets the UL requirements for Type TC cable
7. AMPACITY: Based on not more than three conductors in raceway or cable or earth with an ambient temperature of 30ºC per NEC Table 310.16, the values have been derated
where applicable
8. TEMPERATURE: 90ºC
9. VOLTAGE: 600 V
APPLICATIONS
Used as tray cable where extra flexibility and confined space requirements are involved in the installation.

2ZN-1802, 2ZN-1803, 2ZN-1804, 2ZN-1805, 2ZN-1807, 2ZN-1809, 2ZN-1812, 2ZN-1815, 2ZN-1819, 2ZN-1825, 2ZN-1830, 2ZN-1837, 2ZN-1602, 2ZN-1603, 2ZN-1604, 2ZN-1605, 2ZN-1607, 2ZN-1609, 2ZN-1612, 2ZN-1615, 2ZN-1619, 2ZN-1625, 2ZN-1630, 2ZN-1637, 2ZN-1402, 2ZN-1403, 2ZN-1404, 2ZN-1405, 2ZN-1407, 2ZN-1409, 2ZN-1412, 2ZN-1415, 2ZN-1419, 2ZN-1425, 2ZN-1430, 2ZN-1437, 2ZN-1202, 2ZN-1203, 2ZN-1204, 2ZN-1205, 2ZN-1207, 2ZN-1209, 2ZN-1212, 2ZN-1215, 2ZN-1219, 2ZN-1225, 2ZN-1230, 2ZN-1237

Control Cable PVC Nylon Neoprene en: Tijuana, Rosarito, Mexicali, Ensenada, Tecate, San Luis Rio Colorado, Son, La Paz, BCS, Los Cabos BCS

Etiquetado con: , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,
Publicado en: Cable y Alambre, Wire and Cable

Deja una respuesta

Tu dirección de correo electrónico no será publicada. Los campos obligatorios están marcados con *

*

Descarga Aquí este Catálogo
Subscribase a este sitio