PVC Nylon PVC Shielded

PVC Nylon PVC Shielded

Control Cable PVC Nylon PVC Shielded

PVC Nylon PVC Shielded

1602S, 1603S, 1604S, 1605S, 1607S, 1402S, 1403S, 1404S, 1405S, 1407S, 1202S, 1203S, 1204S, 1205S, 1207S

Somos Especialistas en Cables. Distribuimos en toda la Republica Mexicana: Innovative Trade Center, Tel: (664) 621 33 36 / 621 30 09 ventas@innovative.com.mx, soporte@innovative.com.mx, Tijuana, B. C. www.innovative.com.mx

Control Cable PVC Nylon PVC Shielded

aislamiento PVC-nylon
blindado
El forro de PVC
90 ° C, 600 V
ESPECIFICACIONES
1. CONDUCTORES: Clase B Trenzado de cobre desnudo según UL 83 y 62
2. AISLAMIENTO: Policloruro de vinilo (PVC) por UL Tipo 62 para TFFN (16 AWG) o UL 83 para el tipo THWN o THHN, espesor nominal es de 15 milésimas de pulgada
3. Chaqueta Aislante: Cada conductor aislado está encamisado con la reunión de nylon UL Tipo 62 para TFFN o UL 83 para el tipo THWN o THHN, espesor mínimo es de 4 milésimas de pulgada
4. CÓDIGO DE COLORES: ICEA Método 1, Tabla E-2 (anteriormente K-2)
5. Montaje: Los conductores están cableados con cargas cuando sea necesario para hacer que ronda
6. Blindaje: aluminio / poliéster helicoidalmente aplica con hilo de drenaje de cobre estañado
7. CHAQUETA EN GENERAL: La luz solar resistente al cloruro de polivinilo (PVC) por UL 1277
8. NORMAS: cumple con UL 1277 Requisitos para los cables que tienen conductores P tipo THWN o THHN (TFFN), los cables se enumeran para el entierro directo y cumplen con la norma IEEE 1202, IEE 383
y UL 1685. 70.000 BTU / hr pruebas de llama
9. AMPACIDAD: Basado en no más de tres conductores en la pista de rodadura cable o tierra con una temperatura ambiente de 30 ° C por la Tabla NEC 310.16, los valores se han reducido su potencia
donde corresponda
10.TEMPERATURE: 90 ºC
11.VOLTAGE: 600 V
APLICACIONES
Diseñado por el poder y el control, telemetría, control de relé, el control del tráfico, la distribución, la iluminación y la transmisión de la señal. Puede utilizarse en Clase I, Div. 2 y Clase II, Div. 2
Lugares peligrosos por NEC Art. 501 y 502. Estos cables también cumplen con el art. 392 «Bandejas de cable» y el art. 336 «El poder y la bandeja de cable de control.»

Control Cable PVC Nylon PVC Shielded

PVC-nylon insulation
Shielded
PVC jacket
90°C, 600 V
SPECIFICATIONS
1. CONDUCTORS: Class B stranded bare copper per UL 83 and 62
2. INSULATION: Polyvinyl Chloride (PVC) per UL 62 for Type TFFN (16 AWG) or UL 83 for Type THWN or THHN wire, nominal thickness is 15 mils
3. INSULATION JACKET: Each insulated conductor is jacketed with nylon meeting UL 62 for Type TFFN or UL 83 for Type THWN or THHN wire, minimum thickness is 4 mils
4. COLOR CODE: ICEA Method 1, Table E-2 (formerly K-2)
5. ASSEMBLY: Conductors are cabled with fillers where necessary to make round
6. SHIELDING: Aluminum/polyester helically applied with tinned copper drain wire
7. OVERALL JACKET: Sunlight-resistant Polyvinyl Chloride (PVC) per UL 1277
8. STANDARDS: Meets UL 1277 requirements for Type TC cables having THWN or THHN (TFFN) conductors, cables are listed for direct burial and meet the IEEE 1202, IEE 383
and UL 1685. 70,000 Btu/hr flame tests
9. AMPACITY: Based on not more than three conductors in raceway or cable or earth with an ambient temperature of 30°C per NEC Table 310.16, the values have been derated
where applicable
10.TEMPERATURE: 90ºC
11.VOLTAGE: 600 V
APPLICATIONS
Designed for power and control, telemetering, relay control, traffic control, switching, lighting and signal transmission. May be used in Class I, Div. 2 and Class II, Div. 2
Hazardous Locations per NEC Art. 501 and 502. These cables also conform to Art. 392 «Cable Trays» and Art. 336 «Power and Control Tray Cable.»

2A-1602S, 2A-1603S, 2A-1604S, 2A-1605S, 2A-1607S, 2A-1402S, 2A-1403S, 2A-1404S, 2A-1405S, 2A-1407S, 2A-1202S, 2A-1203S, 2A-1204S, 2A-1205S, 2A-1207S

PVC Nylon PVC Shielded en: Tijuana, Rosarito, Mexicali, Ensenada, Tecate, San Luis Rio Colorado, Son, La Paz, BCS, Los Cabos BCS

Etiquetado con: , , , , , , , , , , , , , , , , , , , , , , , , , ,
Publicado en: Cable y Alambre, Wire and Cable

Deja una respuesta

Tu dirección de correo electrónico no será publicada. Los campos obligatorios están marcados con *

*

Descarga Aquí este Catálogo
Subscribase a este sitio